230
OPTIONS
8.1 Option List
8.1.1 Stand-alone options
Name Type Application, Specifications, etc.
Applicable
Inverter
Parameter unit
(8 languages)
FR-PU04
Interactive parameter unit using LCD display (For use in
Japanese, English, German, French, Spanish, Italian, Swedish
and Finnish)
Common to
all models
Parameter unit
connection cable
FR-CB2 Cable for connection of the operation panel or parameter unit.
Heatsink outside
attachment
FR-A5CN
Used to place only the heat generating section of the inverter in
the back of the control box.
1.5K to 55K,
according to
capacity
Totally enclosed
structure attachment
FR-A5CV
By installing this option, the inverter meets the totally enclosed
structure specifications (IP40).
0.4K to 22K,
according to
capacity
Attachment for conduit
connection
FR-A5FN Used to connect a conduit directly.
30K to 55K,
according to
capacity
FR-A200E series
installation interchange
attachment
FR-A5AT
Mounting plate used to make the mounting dimensions identical to
those of the FR-A200<EXCELLENT> series.
0.4K to 55K,
according to
capacity
EMC Directive
compatible noise filer
(Note 3)
SF Noise filer conforming to the EMC Directive (EN50081-2)
0.4 to 55K,
according to
capacity
High-duty brake resistor
FR-ABR-(H)
(Note 1)
Used to improve the braking capability of the brake built in the
inverter.
0.4K to 7.5K,
according to
capacity
Surge voltage
suppressing filter
FR-ASF-H Suppresses surge voltages on the inverter output side.
0.4 to 55K,
according to
capacity
Power factor improving
DC reactor
FR-BEL-(H)
(Note 1)
Used to improve the inverter input power factor (overall power
factor about 95%) and cooperate with the power supply.
0.4K to 55K,
according to
capacity
Power factor improving
AC reactor
FR-BAL-(H)
(Note 1)
Used to improve the inverter input power factor (overall power
factor about 90%) and cooperate with the power supply.
0.4K to 55K,
according to
capacity
Radio noise filter
FR-BIF-(H)
(Note 1)
For radio noise reduction. Leakage current 4mA.
Common to
all models
Line noise filter
FR-BSF01
For line noise reduction (applies to small capacities of 3.7kW or
less)
FR-BLF For line noise reduction
BU brake unit
BU-1500 to 15K,
H7.5K to H30K
Used to improve the braking capability of the inverter (for high-
inertia load or negative load).
According to
capacity
Brake unit
FR-BU-15K to 55K,
H15K to H55K
Used to improve the braking capability of the inverter (for high-
inertia load or negative load). Use the brake unit and resistor unit
together.
Resistor unit
FR-BR-15K to 55K,
H15K to H55K
Power regeneration
converter
FR-RC-15K to 55K,
H15K to H55K
High-function brake unit which can return motor-generated
braking energy to the power supply.
Power regeneration
common converter
FR-CV 7.5K to 30K(-
AT), 37K, 55K, H7.5K
to H30K(-AT), H37K,
H55K (Note 5)
High function unit that can regenerate the braking energy
generated by the motor to the power supply in common converter
system.
FR-CV dedicated
stand-alone reactor
FR-CVL-7.5K to 55K,
H7.5K to H55K
FR-CV dedicated power cooperative reactor.
High power factor
converter
FR-HC7.5K to 55K,
H7.5K to H55K
The high power factor converter switches the converter circuit on-
off to convert the input current waveform into a sine wave to
suppress harmonics considerably. (Used with the standard
accessories.)