242
APPENDIX
Communication
functions
117 Station number 11 91 1
118 Communication speed 12 92 1
119 Stop bit length/data length 13 93 1
120 Parity check presence/absence 14 94 1
121 Number of communication retries 15 95 1
122 Communication check time interval 16 96 1
123 Waiting time setting 17 97 1
124 CR, LF presence/absence selection 18 98 1
PID control
128 PID action selection 1C 9C 1
129 PID proportional band 1D 9D 1
130 PID integral time 1E 9E 1
131 Upper limit 1F 9F 1
132 Lower limit 20 A0 1
133 PID action set point for PU operation 21 A1 1
134 PID differential time 22 A2 1
Commercial power
supply-inverter
switch-over
135
Commercial power supply-inverter switch-over
sequence output terminal selection
23 A3 1
136 MC switch-over interlock time 24 A4 1
137 Start waiting time 25 A5 1
138
Commercial power supply-inverter switch-over
selection at alarm occurrence
26 A6 1
139
Automatic inverter-commercial power supply
switch-over frequency
27 A7 1
Backlash
140 Backlash acceleration stopping frequency 28 A8 1
141 Backlash acceleration stopping time 29 A9 1
142 Backlash deceleration stopping frequency 2A AA 1
143 Backlash deceleration stopping time 2B AB 1
Display
144 Speed setting switchover 2C AC 1
145 PU display language selection
Additional
functions
148 Stall prevention operation level at 0V input 30 B0 1
149 Stall prevention operation level at 10V input 31 B1 1
Current
detection
150 Output current detection level 32 B2 1
151 Output current detection period 33 B3 1
152 Zero current detection time 34 B4 1
153 Zero current detection period 35 B5 1
Sub functions
154
Voltage reduction selection during stall prevention
operation
36 B6 1
155 RT signal activated condition 37 B7 1
156 Stall prevention operation selection 38 B8 1
157 OL signal waiting time 39 B9 1
158 AM terminal function selection 3A BA 1
Additional
function
160 User group read selection 00 80 2
Restart after
instantaneous
power failure
162
Automatic restart after instantaneous power
failure selection
02 82 2
163 First cushion time for restart 03 83 2
164 First cushion voltage for restart 04 84 2
165 Restart stall prevention operation level 05 85 2
Initial
monitor
170 Watt-hour meter clear 0A 8A 2
171 Actual operation hour meter clear 0B 8B 2
User
functions
173 User group 1 registration 0D 8D 2
174 User group 1 deletion 0E 8E 2
175 User group 2 registration 0F 8F 2
176 User group 2 deletion 10 90 2
Function
Parameter
Number
Name
Data Codes
Read Write
Link Parameter Extension Setting
(Instruction code 7F/FF)