Furuno CH-270 SONAR User Manual


 
3. VERTICAL SCAN MODE
3-13
4. Press or to adjust TVG distance, considering sea conditions. The larger the figure
the greater the distance at which the TVG works.
TVG
Distance
Setting
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
. . . .
10.0
Meters 3 8 20 40 60 100 130 160 200 250 320
. . . .
1000
Feet 10 30 70 130 210 330 410 520 660 820 1040
3280
Passi/braza 2 5 10 20 40 60 80 100 120 150 180
600
Fathoms
5 10 20 40 60 80 100 110 140 170
550
5. Press or to close the dialog box and return to the VERT menu.
6. To suppress reflections from the sea surface or plankton, choose TVG LEVEL and then
press .
7. Press or to adjust TVG LEVEL, considering sea conditions. The larger the figure
the less the gain over distance.
8. Press the [MENU] key to register your selection and close the menu.
Wrong Correct Level too high Distance too high
Examples of proper and improper TVG