3. Select the desired option and press
MENU. The Pressure Range menu
will appear with the following options: 0-30 psi, 0-60 psi, 0-80 psi and
0-100 psi.
4. Select the desired PSI range and press
MENU.
Warning Threshold
When you set a Warning Threshold for a pressure sensor, a pop-up
window will appear and an alarm will sound when pressure exceeds a
preset pressure level of your choosing.
NOTE:
Warning Thresholds may be set to monitor Boost Pressure, Engine
Water Pressure, Oil Pressure, Fuel Pressure and Transmission Oil
Pressure.
To set a warning threshold:
1. Press MENU, select SYSTEM SETUP and press MENU.
2. Highlight
BUS DEVICES and press MENU.
3. Select the desired pressure sensor and press
MENU. Highlight WRNING
TRHLD and press MENU.
4. Use the
UP and DOWN keys to select the desired PSI level. Depress
the
DOWN key to turn off a warning threshold. The threshold will be set
to Off by default.
5. When the threshold is set to the desired level, press
MENU.
Reset
The reset command switches pressure sensor settings (alarms and
configuration) to default values.
To reset EP-90R values:
1. Press MENU, select SYSTEM SETUP and press MENU.
2. Highlight
BUS DEVICES and press MENU. Select a configured pressure
sensor and press
MENU.
3. The pressure sensor menu will appear. Highlight
RESET and press
MENU. The following message will appear: Press Menu to Rst Values.
You will be taken back to the Bus Devices list where the sensor will be
shown as PTT:S (Pitot Speed).