9. When all tanks have been configured, highlight the
SET CONFIGURATION
button and press
ENTER. The following confirmation message will
appear: Are you sure you wish to change the bus configuration? Choose
YES and press ENTER, Press EXIT to return to the main display.
1 Engine/1Tank highlighted on Engine and Tank Configuration
menu (left). Starboard highlighted on Tank Select menu (center).
Tank Size set to 40 gallons (right).
9. When all tanks have been configured, highlight the SET CONFIGURATION
button and press
ENTER. The following confirmation message will
appear: Are you sure you wish to change the bus configuration? Choose
YES and press ENTER, Press EXIT to return to the main display.
EP-90R Pressure Sensor Configuration
The Location and Pressure Type menus will be used when configuring
you EP-90R. You can also change the sensor's Device Name.
Device Name
You can change how your pressure sensor will be displayed on your
unit's NMEA 2000 Devices list by inputting a customized device name
in the Device Name dialog box.
NOTE:
Changing the Device Name only will affect the way the EP-90R is
shown on your display unit. The customized device name will not
be seen by other devices or display units on the NMEA 2000
network.
To change Device Name:
1. Press MENU twice, select NMEA 2000 or NETWORKING and press ENTER.
2. Highlight
BUS SETUP and press ENTER. Select the desired pressure
sensor from the Bus Devices list and press
ENTER.
3. Device Name will be highlighted. Press
ENTER to access the Device
Name dialog box.