Lowrance electronic EP-90R Marine Instruments User Manual


 
21
Pressure Range (Analog Pages only)
From the Single, Dual and Quad Analog pages, you can set pressure
ranges for Boost, Oil, Fuel and Transmission Oil Pressure.
To set pressure range:
1. From an analog page, press MENU, select SYSTEM SETUP and press
ENTER.
2. Highlight
PRESS RANGES (Pressure Ranges) and press ENTER. The
Select Pressure menu with the following options: Eng Water Pressure,
Eng Oil Pressure, Fuel Pressure, Eng Bst Press (Engine Boost
Pressure) and Trns Oil Press (Transmission Oil Pressure).
3. Select the desired option and press
ENTER. The Pressure Range
menu will appear with the following options: 0-15 psi, 0-30 psi, 0-60
psi, 0-80 psi and 0-100 psi.
4. Select the desired PSI range and press
ENTER.
Warning Threshold
When you set a Warning Threshold for a pressure sensor, a pop-up
window will appear and an alarm will sound when pressure exceeds a
preset pressure level of your choosing.
NOTE:
Warning Thresholds may be set to monitor Boost Pressure, Engine
Water Pressure, Oil Pressure, Fuel Pressure and Transmission Oil
Pressure.
To set a warning threshold:
1. Press MENU, select SYSTEM SETUP and press ENTER.
2. Highlight
BUS DEVICES and press ENTER.
3. Select the desired pressure sensor and press
ENTER.
4. Highlight
WRNG THRESHLD and press ENTER.
5. Use the
UP and Down KEYS to input the desired PSI level for the
threshold. Press
ENTER. You will be taken back to the Bus Devices list.
6. Press
EXIT repeatedly to return to the main display.
Reset Values
The Reset Values command switches pressure sensor settings (Alarms
and Configuration) to default values.