Mitsubishi Electronics FR-E5NC Marine Battery User Manual


 
COMMUNICATION SPECIFICATIONS
25
Device
No.
Signal Description
RY10
RY11
RY12
RY13
RY14
RY15
RY16
RY17
RY18
RY19
Reserved (Note 5) Reserved for the system.
RY1A Error reset request flag
If the error reset request flag (RY1A) is switched on only when an inverter fault occurs,
the inverter is reset and the error status flag (RX1A) switches off.
Note: 3. While the set frequency designation (RYD) is on, the set frequency (RW
W1
) value is always returned.
4. If these commands are switched on simultaneously, only one of these is executed.
5. The reserved input signal should be off. (Enter 0)