Mitsubishi Electronics FR-E5NC Marine Battery User Manual


 
PROGRAMMING EXAMPLES
40
6.8 Running Frequency Setting Program Example
1) The following program changes the running frequency of station 2 inverter to 50.00Hz.
Set frequency: K5000 (decimal)
The reply code at the time of instruction code execution is set to D2. (Refer to page 32.)
Writes set frequency to RWw
5
.
SET M303
M9036
FROM 0000
H
00E2
H
M200 2
K
PLS M302
M303
FROM 0000
H
02E6
H
D2 1
K
MOV 5000
K
D100
TO 0000
H
01E5
H
D100 1
K
26
4
5
X0000 X000F X0001 X0020
M302
K4
SET M113
M213
66
RST M113
RST M303
TO 0000
H
0162
H
M100
K4
2
K
M9036
82
36
4
3
Write setting
Switches on the frequency setting command
RAM (RY2D).
Switches off the frequenc
y
settin
g
command
(
RY2D
)
.
Reads the remote input (RX20 to RX3F)
data of buffer memory to M200-M231.
Reads reply code (RWr
6
) to D2 when the frequency
setting completion (RX2D) switches on.
Writes M100-M131 data to the remote outputs
(RY20 to RY3F) of buffer memory.