Oceanic 4.5849 Scuba Diving Equipment User Manual


 
18
F.10 v.3 OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5380-r01 (7/15/14)
Set SRT (Surface Recovery Time) Alarm, information includes (Fig. 29):
> Graphic SRT.
> Recovery Time (min:sec) with SURF & TIME icons.
> Graphic OFF (or ON), flashing upon access.
• A (< 2 sec) - to step forward through the selections of OFF, ON, and SEt.
• M (< 2 sec) - to step back through the selections.
S (2 sec) - to step back to Set Audible.
• S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set EDT Alarm.
> If SEt is saved, the Minute digits will flash.
• A (hold) - to scroll upward through the Minute Set Points at a rate of 8 per second from 0: to 30: in increments of 1 minute.
• A (< 2 sec) - to step upward through the Minute Set Points one at a time.
• M (< 2 sec) - to step back through the Minute Set Points one at a time.
S (2 sec) - to step back to SEt flashing.
• S (< 2 sec) - to save the Minute setting and flash the Seconds digits.
• A (hold) - to scroll upward through the Second Set Points at a rate of 8 per second from :00 to :59 in increments of 1 second.
• A (< 2 sec) - to step upward through the Second Set Points one at a time.
• M (< 2 sec) - to step back through the Second Set Points one at a time.
S (2 sec) - to step back to the Minutes digits flashing.
• S (< 2 sec) - to save the min:sec setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Set EDT (repeating Elapsed Dive Time) Alarm, information includes (Fig. 30):
> Graphic EDT.
> Time (min:sec) with TIME icon.
> Graphic OFF (or ON), flashing upon access.
• A (< 2 sec) - to step forward through the selections of OFF, ON, and SEt.
• M (< 2 sec) - to step back through the selections.
• S (2 sec) - to step back to Set SRT Alarm.
• S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set RDI Alarm.
> If SEt is saved, the Minutes digits will flash.
• A (< 2 sec) - to step upward through the Minute Set Points one at a time from 0: to 9: in increments of 1 minute.
• M (< 2 sec) - to step back through the Minute Set Points one at a time.
S (2 sec) - to step back to SEt flashing.
• S (< 2 sec) - to save the Minute setting and flash the Seconds digits.
• A (hold) - to scroll upward through the Second Set Points at a rate of 8 per second from :00* to :59 in increments of 1 second.
*Starts at :10 (10 seconds minimum) when Minutes are set for 0.
• A (< 2 sec) - to step upward through the Second Set Points one at a time.
• M (< 2 sec) - to step back through the Second Set Points one at a time.
S (2 sec) - to step back to the Minutes digits flashing.
• S (< 2 sec) - to save the min:sec setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Set RDI (Repeating Depth Interval) Alarm, information includes (Fig. 31):
> Graphic RDI.
> Depth interval with FT (or M) icon.
> Graphic OFF (or ON), flashing upon access.
• A (< 2 sec) - to step forward through the selections of OFF, ON, and SEt.
• M (< 2 sec) - to step back through the selections.
• S (2 sec) - to step back to Set EDT Alarm.
• S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set DD1 Alarm.
> If SEt is saved, the Depth digits will flash.
• A (hold) - to scroll upward through the Depth Set Points at a rate of 8 per second from 10 to 100 FT (3 to 33 M) in increments
of 1 FT (3 M).
• A (< 2 sec) - to step upward through the Set Points one at a time.
• M (< 2 sec) - to step back through the Set Points one at a time.
S (2 sec) - to step back to SEt flashing.
• S (< 2 sec) - to save the setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
Fig. 31 - SET RDI ALARM
Fig. 30 - SET EDT ALARM
Fig. 29 - SET SRT ALARM