Oceanic 4.5849 Scuba Diving Equipment User Manual


 
19
F.10 v.3 OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5380-r01 (7/15/14)
Set DD1 (Descending Depth Alarm, DD2 & DA3 similar), information includes (Fig. 32):
The Depth Alarms can only be set at progressively deeper depths with DD2 deeper than DD1 and DD3 deeper than DD2, then any
of the alarms can be set OFF or ON as needed.
> Graphic DD1.
> Depth with MAX and FT (or M) icons.
> Set Point OFF (or ON), flashing upon access.
• A (< 2 sec) - to step forward through the selections of OFF, ON, and SEt.
• M (< 2 sec) - to step back through the selections.
• S (2 sec) - to step back to Set RDI Alarm.
• S (< 2 sec) - to save the setting.
> If OFF or ON is saved, operation will advance to Set DD2 Alarm (to Set DD3 when setting DD2, then to the Set Alarms
Lead-in when setting DD3).
> If SEt is saved, the Depth digits will flash.
• A (hold) - to scroll upward through the Depth Set Points at a rate of 8 per second from 10 to 330 FT (3 to 100 M) in increments
of 1 FT (1 M).
• A (< 2 sec) - to step upward through the Set Points one at a time.
• M (< 2 sec) - to step back through the Set Points one at a time.
S (2 sec) - to step back to SEt flashing.
• S (< 2 sec) - to save the Depth setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved.
------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------
SET UTILITIES
Sequence: Lead-in >> Units >> Wet Activation >> Water Type >> Backlight Duration >> DSD >> BDSI.
• A (< 2 sec), while viewing Set Alarms Lead-in, to access Set Utilities Lead-in.
The Wet Activation feature allows you to turn the disable activation of Dive Mode during activities when you may be using Watch
features not involved with diving.
The Water Type selection adjusts Depth calibration to accommodate activities in fresh or sea/salt water.
The Backlight Duration determines how long the Backlight will be On when activated by pressing the L button.
The DSD (Dive Start Depth) feature allows you to select the Depth at which Dive Mode will be activated upon descent. Regardless
of the DSD set, every dive ends upon ascent above 2 FT (0.6 M) for the BDSI set.
The BDSI (Between Dive Surface Interval) feature allows you to select the time interval between surfacing and descending that
determines whether the descent is a new dive. Short intervals may be preferred for some activities and longer intervals for others,
thus a selection may be helpful.
At any time while entering settings -
M (2 sec), or 2 minutes of no button action, will revert to SURF MAIN.
L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
Set Utilities Lead-in, information includes (Fig. 33):
> Graphics GoTo SEt U.
S (< 2 sec) - to access Set Audible.
A (< 2 sec) - to step forward to ID-SN.
M (< 2 sec) - to step back to Set Alarms Lead-in.
Set Units, information includes (Fig. 34):
> Graphic UNIT.
> FT icon and °F (or M and °C), flashing.
• A or M (< 2 sec) - to toggle between Imperial and Metric.
S (2 sec) - to step back to Set Utilities Lead-in.
• S (< 2 sec) - to save the setting and access Set Wet Activation.
Set Wet Activation, information includes (Fig. 35):
> Graphics WET ACt.
> Graphic OFF (or ON), flashing.
• A or M (< 2 sec) - to toggle between OFF and ON.
S (2 sec) - to step back to Set Units.
• S (< 2 sec) - to save the setting and access Set Water Type.
Fig. 33 - SET UTILITIES
LEAD-IN
Fig. 34 - SET UNITS
Fig. 35 - SET WET
ACTIVATION
Fig. 32 - SET DD ALARM