S01PEQOT1,2,1
Query current type setting of
parametric EQ on output B , band
1.
S01PEQOTB,1,t , where t is the current
setting of the type parameter for the
parametric EQ on output B , band 1. If the
type parameter of this filter is set to the same
value given in the example above, then the
status message will be S01PEQOTB,1,1 .
8.128. PHANTOM -- Enable Phantom Power on Input 1
This command sets or queries the status of phantom power on microphone input 1.
This command is a channel boolean command. See
Section 6.3 and Section 6.1 for more information
on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01PHANTOM11
Enable phantom power for input
channel 1.
S01PHANTOM11
S01PHANTOM10
Disable phantom power for input
channel 1.
S01PHANTOM10
S01PHANTOM12
Toggle phantom power state for
input channel 1.
S01PHANTOM1x , where x is 0 or 1
depending on the current state of phantom
power on input channel 1.
S01PHANTOM1?
Query state of phantom power for
input channel 1.
S01PHANTOM1x , where x is 0 or 1
depending on the current state of phantom
power on input channel 1.
8.129. PHONE -- Take Phone On-Hook or Off-Hook
This command sets or queries the on-hook status of the phone interface.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
Example Description Status Message
S01PHONE0
Put phone interface on-hook (hang up
phone interface).
S01PHONE0
S01PHONE1
Take phone interface off-hook (pick up
phone interface).
S01PHONE1