Polycom RS-232 Waterskis User Manual


 
24 boolean values is returned with the first value indicating the state of the first logic input, the
second value indicating the state of the second logic input, and so on.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
S01LI*?
Query current state
of logic inputs.
S01LI*111010100010111100001110 , this is an exapmle
response, the actual values will depend on the actual states on the
logic inputs.
8.76. LIA -- Assign Action for when Logic Input is Activated
This function assigns a single command to be executed when a given logic input changes from the
inactive state to the active state. Typically, the inactive state is logic high ('1') and the active state is
logic low ('0'). This is commonly referred to as active low. Acitve low is considered normal because a
closed switch would ground the input and a closed switch would normally be considered active. This
polarity setting can be changed via the
LIP command.
A single command can be assigned to each of three conditions occurring on the logic pin: a change to
the active state, a change to the inactive state, and a repeating command when the pin is held in the
active state. The LIA command assigns a single command to the logic pin that is executed when the
logic pin changes to the active state.
Although only one command can be assigned to the state change, the command may be a
MACROX or
MACROQ command. Since up to 256 commands can be stored in each macro, this gives the effect of
having up to 256 commands execute when the logic pin changes state. The command associated with
the state change can also be a
PRESETX or PRESETQ. This makes it easy to reconfigure the device for
different rooms based on external logic settings.
The
BROADA is also useful in logic pin assignments. The BROADA command transmits a command to
another device on the EF Bus, so you can effectively make a logic pin state change on one device
cause an action to occur on another device.
ERROR#074 will be generated if the assigned command is one that writes non-volatile memory, and
the pin will not actually be assigned.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.