Polycom RS-232 Waterskis User Manual


 
S01PEQIAB,1,?
Query the
current
parameter
settings for the
parametric eq
filter on input B ,
band 1.
S01PEQIAB,1,t,f,b,g,s,e , where
the parameters t, f, b, g, s, and e
correspond to the current settings of the
type, frequency, bandwidth, gain, slope,
and enabled parameters, respectively. If
this filter was set to the same parameters
as given in the above example, the status
message would be
S01PEQIAB,2,1,1250,40,-20,1,1 .
8.115. PEQIB -- Set Bandwidth Parameter for Specified
Parametric EQ Input Stage
This command sets or queries the bandwidth parameter (in 1/100th octaves) for the parametric
equalizer (EQ) filters on input channels 1, A, B, and T . Each channel has five bands of parametric EQ
that can be independently controlled.
The minimum and maximum values for the bandwidth parameter are 5 and 200, respectively.
This command has the same format and restrictions as the
PEQIA command except that only one
parameter, the bandwidth, is specified instead of all the parameters. See the
PEQIA command for
more information. To set the bandwidth parameter for an output parametric EQ filter, use the
PEQOB
command. To set all the parameters for an output parametric EQ filter, use the
PEQOA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01PEQIB1,2,40
Set bandwidth of parametric EQ
on input 1 , band 2 to 40
1/100th octaves.
S01PEQIB1,2,40
S01PEQIBB,1,?
Query current bandwidth setting
of parametric EQ on input B ,
band 1.
S01PEQIBB,1,b , where b is the current
setting of the bandwidth parameter for the
parametric EQ on input B , band 1. If the
bandwidth parameter of this filter is set to the
same value given in the example above, then
the status message will be S01PEQIBB,1,40
.
8.116. PEQIE -- Set Enabled Parameter for Specified
Parametric EQ Input Stage
This command sets or queries the enabled parameter (0 = filter is disabled, 1 = filter is enabled) for