Simrad AP25 Autopilot
34 20221495F
STANDBY
Non-Follow Up
steering mode
Heading to be
maintained by rudder
Heading to be
maintained by rudder
and thruster
AUTO mode
Heading maintained by
rudder
Heading maintained
by rudder and thruster
Note ! When operating an On/Off thruster be aware that most electrical
thrusters have a built in thermal cut-off switch. The switch will
shut off the motor if it is overheating and re-engage it when it
has cooled down. The water temperature also affects the running
time. The On/Off thruster may only run for a few minutes, and
the total running time for a longer period should be limited by
increasing the thruster sensitivity value (see page
57).