H8DMT/H8DMT-IBX/H8DMT-F/H8DMT-IBXF User’s Manual
4-8
Table 4-11. Hardware Health Monitor Submenu
Menu Item Description
CPU Overheat
Alarm
Use the "+" and "-" keys to set the CPU temperature threshold to between 65
o
and 90
o
C. When this threshold is exceeded, the overheat LED on the chassis
will light up and an alarm will sound. The LED and alarm will turn off once the
CPU temperature has dropped to 5 degrees below the threshold set. The default
setting is 72
o
C.
System Fan Monitor Submenu
Fan Speed
Control
This feature allows you to determine how the system will control the speed of the
onboard fans. Select W
ORKSTATION if your system is used as a Workstation.
Select S
ERVER if your system is used as a server. Select Disable to disable the
fan speed control function to allow the onboard fans to continuously run at full
speed (12V). The options are 1) Disable (Full Speed) 2) 3-
PIN (SERVER) and 3)
3-
PIN (WORKSTATION).
FAN1 Speed
through FAN4
Reading
The speeds of the onboard fans (in rpm) are displayed here.
Other
Information
Other items in the submenu are systems monitor displays for the following
information:
CPU1 T
EMPERATURE, CPU2 TEMPERATURE (for 2U systems), SYSTEM
T
EMPERATURE, VCOREA, VCOREB (for 2U systems), HT VOLTAGE, CPU1 MEM
VTT, CPU2 M
EM VTT, CPU1 MEM, CPU2 MEM, 12V, 3.3V, VDD, 5V VSB,
MCP55VC
ORE, 1.5V and VBAT.
Table 4-12. IPMI Configuration
Menu Item Description
View BMC System
Event Log
Use the "+" and "-" keys to navigate through the system event log. Pressing the
Enter key will open the following setting:
Clear BMC
System Event Log
Selecting this and pressing the Enter key will clear the BMC system event log.
Set LAN
Configuration
Use the "+" and "-" keys to choose the desired channel number.
IP Address
Use the "+" and "-" keys to select the parameter. The IP address and current IP
address in the BMC are shown.
MAC Address
Use the "+" and "-" keys to select the parameter. The MAC address and current
MAC address in the BMC are shown.
Subnet Mask
Use the "+" and "-" keys to select the parameter. The subnet address and current
subnet address in the BMC are shown.
Set PEF Configuration Submenu
PEF Support
Use this setting to ENABLE or Disable PEF support. When enabled, the following
settings will appear:
BMC Watch Dog
Timer Action
This setting is used to set the Watch Dog function. The options are Disabled,
R
ESET SYSTEM, POWER DOWN and POWER CYCLE.