Xantrex Technology 806-1055-02 806-1840 Marine Battery User Manual


 
28 Freedom HF Installation Guide
Basic Installation Procedures
Step 7: Mounting the Display Panel
The communications cable supplied with the display panel is 25 feet (7.62
meters) long. If you want to replace the cable with one that is shorter, use a
high quality, six-wire telephone extension cable.
Flush mounting the panel on a wall or bulkhead requires an opening that is
approximately 3.25 × 1.25 inches (8.25 × 3.18 cm). About 1.5 inches
(3.81 cm) of free space is required within the wall to accommodate the
depth of the panel. Be sure there is no wiring or other obstructions within
the wall before you make an opening.
To mount the display panel:
1. Choose a location that is dry, out of direct sunlight, free from corrosive
or explosive fumes, and otherwise appropriate for mounting an
electronic device.
2. Tape the mounting template (in the Freedom HF package) to the
mounting surface and mark the locations of the mounting holes and the
area to be cut away.
3. Pilot-drill the mounting holes and cut out the hole in which the panel
will be inserted.
4. Route the communications cable(s) inside the wall and through the
opening.
5. Insert one of the cable’s connectors in either jack on the bottom of the
panel.
6. Place the panel in the opening and secure it with appropriate fasteners.
7. Route the communications cable to the Freedom HF and insert the
connector in the jack located near the battery select dip switch.
IMPORTANT:
Do not route the communications cable in parallel and in
conduit with the AC and DC wires. In situations where the cable must cross
with the AC and DC wires, make sure they cross at a 90° angle to each
other.
Freedom HF Install Guide.book Page 28 Thursday, November 24, 2011 11:06 AM