Bosch Appliances D9112 Marine Radio User Manual


 
D9112 Operation & Installation Manual
Page 41
© 1993 Radionics
74-06144-000-C 2/96
POPIT Labels
Off-board points are numbered 9 to 71 and 73 to 135. The D9112 reserves points 72 and
136 for internal use. You must connect POPITs for points 73 to 135 to expansion loops
connected to POPEX #2.
Four sheets of peel-off POPIT labels are supplied with the D8125 POPEX module. Use
the sheet marked
Vertical Grid for POPEX #1
for points 9 to 71
.
Use the sheet marked
Vertical Grid for POPEX #2
for points 73 to 135
.
Each label has two parts. Place the smaller part, with just the point number on it, on the
POPIT terminal block as shown in Figure 15. Place the larger part with the switch settings
on the POPIT cover. Set the switches and cover the POPIT.
Do not program two POPITs for the same point number. After you program all the points,
perform a walk test. The
Security System Owner's Manual
(74-06633-000)
and the
Security System User's Guide
(71-06141-000) contain instructions for performing a walk
test. If a point does not test, check the programming for a duplicated address.
1 2 3 4 5 6
ZN 101
PX1
1 2 3 4 5 -
ZN 102
PX1
1 2 3 4 - 6
ZN 103
PX1
1 2 3 4 - -
ZN 104
PX1
1 2 3 - 5 6
ZN 105
PX1
1 2 3 - 5 -
ZN 106
PX1
1 2 - 4 5 6
ZN 109
PX1
1 2 - 4 5 -
ZN 110
PX1
1 2 - 4 - 6
ZN 111
PX1
1 2 - 4 - -
ZN 112
PX1
1 2 - - 5 6
ZN 113
PX1
1 - 3 4 5 6
ZN 201
PX1
1 - 3 4 5 -
ZN 202
PX1
1 - 3 4 - 6
ZN 203
PX1
1 - 3 4 - -
ZN 204
PX1
1 - - 4 5 6
ZN 209
PX1
1 - - 4 5 -
ZN 210
PX1
1 - - 4 - 6
ZN 211
PX1
1 - - 4 - -
ZN 212
PX1
PT 12
PT 11PT 13
PT 17
PT 17
PT 10
PT 10PT 13
PT 19
PT 12
PT 09
PT 09
PT 11
PT 20
PT 18
PT 18
PT 19
PT 20
PT 21
PT 25
PT 25
PT 26
PT 26
PT 27
PT 21
Vertical Grid for POPEX #1
(Use this Vertical Grid for D9112 Points 9 to 71)
1 2 3 4 5 6
PT 132
D9112 POINT NUMBER
PLACE SMALL
LABEL ON THIS
TERMINAL
BLOCK
D8112 STYLE ZONEX FORMAT
POPEX MODULE NUMBER
POPIT SWITCH SETTING
D8112
MASTER ZONE 1
D8112
MASTER ZONE 2
Figure 15: POPIT Labels