Bosch Appliances D9112 Marine Radio User Manual


 
D9112 Operation & Installation Manual
Page 9
© 1993 Radionics
74-06144-000-C 2/96
Event Memory
The D9112 uses event memory to store events for each area. You can view the events
for an area at a D1255 Command Center assigned to the area. The D9112 panel clears
the events for an area from event memory and starts storing new events when you
master arm the area.
Event Log
The D9112 stores up to 500 events and event modifiers from all areas in it's event log.
Event modifiers add information about an event to the log. Some events are always
followed by a modifier. For example, the D9112 adds at least two items to the log each
time you arm or disarm an area, the open (or close) event and an event modifier showing
the previous arming state.
All events and their modifiers are stored even if the D9112 does not send a report for
them. You can view the log at a D1255 Command Center, print it locally using the
D9131 Parallel Printer Interface and a parallel printer, or upload it to a D5300 Remote
Account Manager II (RAM II).
See S- View Log in the Security System User's Guide (71-06141-000) for a complete
listing of log events and event modifiers.
EMI/Lightning Transient Protection
The D9112 maintains the Radionics high level of quality and field dependability. Its
design significantly reduces electromagnetic interference and malfunction generally
caused by lightning.
Programming
Use either the Radionics D5200 Programmer, or the D5300 Remote Account Manager II
(RAM II) to program the D9112. Refer to the D9112 Program Entry Guide (74-06145-000)
for programming options.
NCI