Furuno FR-2115-B Marine RADAR User Manual


 
4-3
4.1.2 Connection of external power supply
An external power supply is necessary when the repeater signal is step-by-step type and the
step voltage is below 20 V or output voltage is less than 5 W.
1. Cut the jumper wire JP1 on the GYRO CONVERTER Board when an external power supply
is used.
2. Connect the gyro cable and power cable as shown below.
GYRO CONVERTER Board
[A] 64P1106
1 R2
Either connection
in case of DC
polarity.
J5
2 R1/COM
External Power Supply
20 - 135 VAC
20 - 100 VDC
1S1
2 S2
3 S3
4 T
5 F.G.
Gyrocompass
(Step type)
S1
S2
S3
COM
F.G.
J4
Figure 4-3 Connection of external power supply to GYRO CONVERTER Board
4.1.3 DIP switch, jumper wire settings
Default setting
The default setting of all DIP switches is off and all jumpers wire are set to "#1". (Note that the
jumper wire JP1 is set at #1, #2, and #3.) In those settings the gyrocompass having the
following characteristics can be directly connected; modification of the GYRO CONVERTER
Board is not necessary.
AC synchronous signal: 50/60 Hz
Rotor voltage: 60 to 135 V AC
Stator voltage: 60 to 135 V AC
Gear ratio: 360X
Supply voltage: 30 to 135 V AC
If the specifications of the gyrocompass differ from those mentioned above, change jumper wire
and DIP switch settings on the GYRO CONVERTER Board as appropriate. Settings may be
changed according to gyrocompass specifications (page 4-4) or make and model of
gyrocompass (page 4-5). For the location of DIP switches and jumper wires, see page 4-6.