Furuno FR-2115-B Marine RADAR User Manual


 
vi
SYSTEM CONFIGURATION
Option
FR-2115-B: XN12AF-RSB-0074-062
XN12AF-RSB-0075-062
XN20AF-RSB-0074-062
XN20AF-RSB-0075-062
XN24AF-RSB-0074-062
XN24AF-RSB-0075-062
FR-2125-B: XN12AF-RSB-0074-063
XN12AF-RSB-0075-063
XN20AF-RSB-0074-063
XN20AF-RSB-0075-063
XN24AF-RSB-0074-063
XN24AF-RSB-0075-063
ANTENNA UNIT
Ship's Mains
24/32 VDC
or
100/110/115/220/230 VAC
1
φ, 50/60 Hz
Rectifier
RU-3424
Transformer Unit
RU-1803
440 VAC
1
φ, 50/60 Hz
AC spec or DC spec to be selected.
DC spec
AC spec
Navigator
IEC 61162-1 (Input/Output)
IEC 61162-1 (Input)
Speed Log
Performance
Monitor
PM-30
Slave Display
FMD-8010
Gyrocompass
PROCESSOR UNIT
RPU-11
CONTROL UNIT
RCU-11
MONITOR
RDP-124-M-ES
ARPA Board
ARP-26
Video Plotter
RP-26
Gyro Converter
GC-8
Alarm Kit
OP03-156
I/O Data Sentences
Input: GGA, RMA, RMB, RMC, GLL, ZDA, VBW, VHW, VTG, MWV, VWT, VWR, VDR, DPT,
DBT, DBS, MTW, BWR, BWC, WPT, RTE
Output: RAOSD, RARSD, RATTM