The array modules are designed to operate in the environment defined in Table 4-4 and
Table 4-5 on page 4-7.
Table 4-4 Array Module Environmental Requirements
Condition Parameter
Requirement
E2400 10x and E2400 14x
Temper atur e
Operating Range
10
°
C to 40
°
C (50
°
F to 104
°
F)
Maximum Rate of Change
10
°
C (18
°
F) per hour
Storage Range
-10
°
C to 50
°
C (14
°
F to 122
°
F)
Maximum Rate of Change
15
°
C (27
°
F) per hour
Transit Range
-40
°
C to 60
°
C (-40
°
F to 140
°
F)
Maximum Rate of Change
20
°
C (36
°
F) per hour
Relative Humidity
No condensation
Operating Range 20% to 80%
Storage Range 10% to 90%
Transit Range 5% to 95%
Maximum Dew Point
26
°
C (79
°
F)
Maximum Gradient 10% per hour
Sound
Sound Power 6.0 bels
Sound Pressure 60 dBA
Altitude
(Above Sea Level)
1
Operating and Storage 3000 m (9840 ft.)
Transit 12,000 m (40,000 ft.)
Altitude
(Below Sea Level)
Operating, Storage,
and Transit
30.5 m (100 ft.)
1
If you plan to operate an array module at altitudes between 1000 m to 3000 m (3280 ft. to 9850 ft.) above sea level,
lower the environmental temperature 1.7
°
C (3.3
°
F) for every 1000 m (3280 ft.) above sea level.
Table 4-5 Array Module Heat Dissipation
Model
Low Profile (LP)
18 GB and 36 GB Drives
Half Height (HH)
36 GB and 73 GB Drives
E2400 10x 1187 Btu/hr (0.35 kVA or 347 W) 1221 Btu/hr (0.37 kVA or 357 W)
E2400 14x 1118 Btu/hr (0.328 kVA or 327 W) Not applicable.