StreamLight VF-PS1 Marine Battery User Manual


 
E6581429
C-6
3
1. Press the [F4] key to carry out jog run.
The jog run frequency is displayed on the screen.
(In this example, the operation frequency is set at 5.0Hz.)
Operation continues as long as the [F4] key is pressed,
and it stops when the [F4] key is released.
Functions of function keys
: Switches between Quick mode and Standard Setting mode.
: Goes to the Language selection window.
: Executes a jog run command.
3.3.5 Emergency stop / reset operation
To make an emergency stop or to reset the inverter, follow these steps. An emergency stop can be made when
operation is performed with the terminal board inputs (parameter CMOd=0, 2, 3 or 4).
1. Press the [STOP/RESET] key.
Blinking code “ EOFF ” is displayed in the upper right corner
of the window.
2. Then press the [STOP/RESET] key again.
The Emergency Stop window appears and the blinking code
“E” is displayed.
3. Then press the [STOP/RESET] key again.
The Trip window appears and the blinking code “CLr” is
displayed.
4. Last of all, press the [STOP/RESET] key once again to reset the inverter.
F1
F2
F4
To
p
View Mode
FWD 60.0 Hz JOG
5.0 Hz
Ln
g
Quick
JOG
F1 F2 F4
To
p
View Mode EOFF
FWD 60.0 Hz RUN
60.0 Hz
Emergency stop?
Ln
g
Quick
---
To
p
View Mode
FWD 60.0 Hz Trip
E
Emergency stop
Ln
g
Quick
---
To
p
View Mode
FWD 60.0 Hz Trip
CLr
Trip reset? (STOP-Key)
Ln
g