5
5.1 Displaying details of an item monitored
1. Select/confirm the desired item using the control dial.
(Ex. Select/confirm “Output current”)
The monitor window of the item selected appears.
* Depending on the item selected, no monitor window may be
displayed.
Functions of function keys
: Goes to the Top View Mode.
: Goes to the Parameter Setup Mode.
Q How to use monitor windows
Monitor windows can be broadly classified under the following
three types
<Type of window 1: Displays a value and a graph>
This type of window displays an analog value, such as an
output frequency, output current or output voltage.
(Ex. “Output current”)
It displays the current value in both of numerical form and
graph form.
In addition, the minimum allowable value (min) and the
maximum allowable value (max) are also displayed at
the bottom of the window.
<Type of window 2: Displays information in a graph form>
This type of window displays input/output terminal information
and parts replacement alarm.
(Ex. “Input terminal : S4, S3...R, F”)
It displays the ON/OFF status of each terminal signal or alarm
signal in a graph form.
If the arrow
is moved to a terminal or alarm symbol, the name
of the function assigned to the terminal or the name of the alarm
is displayed.
<Type of window 3: Displays information in a list form>
This type of window displays detailed past trip information.
(Ex. Past trip # 1 (latest))
It displays the conditions under which the inverter was operated
at the occurrence of tripping.
F1
F4
Status Monitor Mode
Input terminal 1 : S4,S3…R,F
ON
OFF
Forward run
To
p
Prm
S4 S3 S2 S1 RES ST R F
Past tri
p
#1
(
latest
)
E :Emer
g
enc
y
sto
p
Sequence number 1
Output frequency 25.0Hz
Rotative direction FWD
Frequency reference 30.0Hz
Output current 40%
To
p
Prm
Out
p
ut current
min=0 max=185
Top Prm
22%
Status Monitor Mode
Out
p
ut current
min=0 max=185
Top Prm
22%
Status Monitor Mode