Fujitsu M9000 Life Jacket User Manual


 
testsb(8)
System Administration 429
The addboard(8), deleteboard(8), or moveboard(8) command is executed
for XSB.
In case an XSB which belongs to the specified PSB is in Unmount or Faulted
status, it may be excluded from the target of diagnosis and may not be shown in
the diagnosis result. In a case like this, use the testsb(8) command to check the
diagnosis result.
In case there are the settings for the warm-up time of the system and the wait
time before system startup, a prompt appears to confirm whether or not it can
ignore these settings to execute the testsb(8) command. Enter "y" to execute the
command or "n" to cancel the command.
The displayed diagnostic results of the testsb(8) command are as follows:
EXAMPLES
EXAMPLE 1 Performs the initial diagnosis on PSB#00.
XSB XSB numbers belonging to the specified PSBs. One XSB number
is displayed for the Uni-XSB type, and four XSB numbers are
displayed for the Quad-XSB type.
Test Status of the initial diagnosis of XSBs. One of the following status
values is displayed:
Unmount No XSB could be recognized because no XSB
is mounted or because an error occurred.
Unknown Not tested.
Testing Initial diagnosis is in progress.
Passed Initial diagnosis ended normally.
Failed An error was detected during the initial
diagnosis. An XSB cannot be used or is in a
degraded state.
Fault XSB error. One or more states are displayed:
Normal Normal state.
Degraded One or more components are degraded. Each
XSB can operate.
Faulted An XSB cannot operate because an error
occurred.
XSCF> testsb 0
Initial diagnosis is about to start, Continue?[y|n] :y
SB#00 power on sequence started.