Furuno GP-1600F Marine GPS System User Manual


 
3–11
3.9 Displaying the Water Temperature Graph
By connecting a water temperature indicator, a water temperature
graph can be displayed.
200k
162
0
50
100
150
200
68.3
CSE 180.0° SPD 16.8kt
DEP 113.6 ft TMP 16.0 °C
3D
12.0V
POS 34° 26.245' N 135° 41.232' E
Depth scale
VRM
Fish school
Seabed
Transmit
frequency
Water
temperature
scale
Water
temperature
graph
Tone bar
Depth
°C
30
20
10
0
Water
temperature
display
Figure 3-16 Water temperature graph
To turn on/off the water temperature graph;
1) Press the [MENU ESC] key.
2) Press [6] key to display VIDEO SOUNDER SETUP menu.
3) Press the [] or [] key to select TEMP GRP.
4) Press the [t] or [s] to select ON or OFF.
5) Press the [MENU ESC] key.