Furuno GP-1600F Marine GPS System User Manual


 
5–7
5.7 SENSOR SETUP menu
The SENSOR SETUP menu provides for selection and calibration
of speed and temperature sensors (optional equipment).
Keying sequence: [MENU ESC] [0] [5]
SENSOR SETUP
SPD SENSOR STW SOG
TEMP SENSOR OWN NMEA
SPD CALIB +00%(-50 ~ +50)
TEMP CALIB +00.0 °C
DEPTH CALIB +0.0 ft
▼▲ :Cursor :+/-
ESC:Esc
Figure 5-9 SENSOR SETUP menu
SENSOR SETUP menu description
SPD SENSOR: Select speed input source; navaid or internal.
TEMP SENSOR: Select device (option) which feeds temperature
data; external or internal.
SPD CALIB: Enter offset to correct speed data.
TEMP CALIB: Enter offset to correct water temperature data.
DEPTH CALIB: Enter offset to correct depth.
5.8 NMEA SETUP menu
This menu selects output data format and type of external device
connected to the GP-1600F.
Keying sequence: [MENU ESC] [0] [6]
NMEA SETUP
FORMAT 183V1.5 183V2.0
EXT DEVICE REM PILOT
▲▼ts:Cursor ESC:Esc
Figure 5-10 NMEA SETUP menu
NMEA SETUP menu description
FORMAT: Select the format of data output to external equipment.
EXT DEVICE: Select external device connected to the GP-1600F.