Mitsubishi Electronics FR-A500L Marine Battery User Manual


 
PARAMETERS
19
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Settin
g
Increments
Factory Setting
Refer To
Page:
<Note9>
52 DU/PU main display data selection
0, 5 to 14, 17, 18, 20,
23, 24, 25, 100
1067
53 PU level display data selection 0 to 3, 5 to 14, 17, 18 1 1 67
54 FM terminal function selection
1 to 3, 5 to 14,
17, 18, 21
1167
55 Frequency monitoring reference 0 to 400Hz 0.01Hz 60Hz<50Hz> 69
Display functions
56 Current monitoring reference 0 to 3600A 0.1A Rated output current 69
57 Restart coasting time 0 to 30 sec, 9999 0.1 sec 9999 70
Automatic
restart
functions
58 Restart cushion time 0 to 60 sec 0.1 sec 1.0 sec 70
Additional
function
59 Remote setting function selection 0, 1, 2 1 0 72
60 Intelligent mode selection 0 to 8 1 0 73
61 Reference I for intelligent mode 0 to 3600A, 9999 0.1A 9999 75
*62 Ref. I for intelligent mode accel. 0 to 150%, 9999 0.1% 9999 75
*63 Ref. I for intelligent mode decel. 0 to 150%, 9999 0.1% 9999 75
64 Starting frequency for elevator mode 0 to 10Hz, 9999 0.01Hz 9999 75
65 Retry selection 0 to 5 1 0 76
66
Stall prevention operation level reduction
starting frequency
0 to 400Hz 0.01Hz 60Hz<50Hz> 77
67 Number of retries at alarm occurrence 0 to 10,101 to 110 1 0 76
68 Retry waiting time 0 to 10 sec 0.1 sec 1 sec 76
69 Retry count display erasure 0

076
70 Special regenerative brake duty 0 to 100% 0.1% 0% 77
71 Applied motor 0 to 8, 13 to 18 1 0 78
72 PWM frequency selection 0, 1, 2 1 1 79
73 0-5V/0-10V selection 0 to 5, 10 to 15 1 1 80
74 Filter time constant 0 to 8 1 1 81
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17 1 14 81
76 Alarm code output selection 0, 1, 2, 3 1 0 83
77 Parameter write disable selection 0, 1, 2 1 0 84
78 Reverse rotation prevention selection 0, 1, 2 1 0 85
Operation selection functions
79 Operation mode selection 0 to 8 1 0 86
80 Motor capacity 0 to 3600kW, 9999 0.1kW 9999 89
81 Number of motor poles 2, 4, 6, 12, 14, 16, 9999 1 9999 89
82 Motor exciting current (Note 6) 0 to , 9999 1 9999 90
*83 Rated motor voltage 0 to 1000V 0.1V 575V 90
84 Rated motor frequency 50 to 120Hz 0.01Hz 60Hz<50Hz> 90
89 Speed control gain 0 to 200% 0.1% 100% 89
90 Motor constant (R1) (Note 6) (Note 6) (Note 6) 9999 90
91 Motor constant (R2) (Note 6) (Note 6) (Note 6) 9999 90
92 Motor constant (L1) (Note 6) (Note 6) (Note 6) 9999 90
93 Motor constant (L2) (Note 6) (Note 6) (Note 6) 9999 90
94 Motor constant (X) (Note 6) (Note 6) (Note 6) 9999 90
95 Online auto tuning selection 0, 1 1 0 96
Motor constants
96 Auto tuning setting/status 0, 1, 101 1 0 90
100 V/F1 (first frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98
101
V/F1 (first frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 98
102 V/F2 (second frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98
103
V/F2 (second frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 98
104 V/F3 (third frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98
105 V/F3 (third frequency voltage) (Note 1) 0 to 1000V 0.1V 0 98
5-point flexible V/F
characteristics
106 V/F4 (fourth frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98