Mitsubishi Electronics FR-A500L Marine Battery User Manual


 
PARAMETERS
21
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Settin
g
Increments
Factory Setting
Refer To
Page:
<Note9>
150 Output current detection level 0 to 200% 0.1% 150% 120
151 Output current detection period 0 to 10 sec 0.1 sec 0 120
152 Zero current detection level 0 to 200% 0.1% 5.0% 121
Current
detection
153 Zero current detection period 0 to 1 sec 0.01 sec 0.5 sec 121
154
Voltage reduction selection during stall
prevention operation
0, 1 1 1 121
155 RT activated condition 0, 10 1 0 122
*156 Stall prevention operation selection 0 to 31 (Odd), 100 1 0 122
157 OL signal waiting time 0 to 25 sec, 9999 0.1 sec 0 124
Sub functions
158 AM terminal function selection
1 to 3, 5 to 14,
17, 18, 21
1 1 124
Additional
function
160 User group read selection 0, 1, 10, 11 1 0 125
162
Automatic restart after instantaneous
power failure selection
0, 1, 2 1 0 125
163 First cushion time for restart 0 to 20 sec 0.1 sec 0 sec 125
164 First cushion voltage for restart 0 to 100% 0.1% 0% 125
Automatic restart after
instantaneous power
failure
*165 Restart stall prevention operation level 0 to 150% 0.1% 150% 125
170 Watt-hour meter clear 0

0 126
Initial
monitor
171 Actual operation hour meter clear 0

0 126
173
User group 1 registration 0 to 999
10
125
174
User group 1 deletion 0 to 999, 9999
10
125
175
User group 2 registration 0 to 999
10
125
User functions
176
User group 2 deletion 0 to 999, 9999
10
125
180
RL terminal function selection 0 to 99, 9999
10
126
181
RM terminal function selection 0 to 99, 9999
11
126
182
RH terminal function selection 0 to 99, 9999
12
126
183
RT terminal function selection 0 to 99, 9999
13
126
184
AU terminal function selection 0 to 99, 9999
14
126
*185
JOG terminal function selection Already Assigned 126
186
CS terminal function selection 0 to 99, 9999
16
126
190 RUN terminal function selection 0 to 199, 9999 1 0 128
191
SU terminal function selection 0 to 199, 9999 1 1 128
192
IPF terminal function selection 0 to 199, 9999 1 2 128
193
OL terminal function selection 0 to 199, 9999 1 3 128
194
FU terminal function selection 0 to 199, 9999 1 4 128
Terminal assignment functions
195
A, B, C terminal function selection 0 to 199, 9999 1 99 128
Additional
function
199
User's initial value setting 0 to 999, 9999 1 0 130
Pr.185 : This terminal is already assigned in Factory. User can not use.