Mitsubishi Electronics FR-A500L Marine Battery User Manual


 
PARAMETERS
22
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Settin
g
Increments
Factory Setting
Refer To
Page:
<Note9>
200
Programmed operation minute/second
selection
0 to 3 1 0 131
201
Program set 1
1 to 10
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
211
Program set 2
11 to 20
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
221
Program set 3
21 to 30
0 to 2: Rotation direction
0 to 400, 9999:Frequency
0 to 99.59: Time
1
0.1Hz
Minute or second
0
9999
0
131
Programmed operation
231
Timer setting 0 to 99.59

0 131
232
Multi-speed setting (speed 8) 0 to 400Hz, 9999 0.01Hz 9999 135
233
Multi-speed setting (speed 9) 0 to 400Hz, 9999 0.01Hz 9999 135
234
Multi-speed setting (speed 10) 0 to 400Hz, 9999 0.01Hz 9999 135
235
Multi-speed setting (speed 11) 0 to 400Hz, 9999 0.01Hz 9999 135
236
Multi-speed setting (speed 12) 0 to 400Hz, 9999 0.01Hz 9999 135
237
Multi-speed setting (speed 13) 0 to 400Hz, 9999 0.01Hz 9999 135
238
Multi-speed setting (speed 14) 0 to 400Hz, 9999 0.01Hz 9999 135
Multi-speed operation
239
Multi-speed setting (speed 15) 0 to 400Hz, 9999 0.01Hz 9999 135
240
Soft-PWM setting
0, 1
1 1 135
Sub functions
244
Cooling fan operation selection
0, 1
1 0 135
Stop selection
function
250
Stop selection 0 to 100 sec, 9999 0.1 sec 9999 135
Sub
functions
251
Start holding time 0 to 10 sec, 9999 0.1 sec
9999
136
261
Power failure stop selection 0, 1
1 0 137
262
Subtracted frequency at deceleration
start
0 to 20Hz
0.01Hz 3Hz 137
263
Subtraction starting frequency 0 to 120Hz, 9999
0.01Hz 60Hz
<50Hz>
137
264
Power-failure deceleration time 1
0 to 3600/
0 to 360 sec
0.1 sec/
0.01 sec
5 sec
137
265
Power-failure deceleration time 2
0 to 3600/
0 to 360 sec, 9999
0.1 sec/
0.01 sec
9999 137
Power failure stop function
266
Power-failure deceleration time switch-
over frequency
0 to 400Hz
0.01Hz 60Hz 137
Selection
function
270
Stop-on-contact/load torque high-speed
frequency control selection
0, 1, 2, 3 1 0 139
271
High-speed setting maximum current 0 to 200% 0.1% 50% 140
272
Mid-speed setting minimum current 0 to 200% 0.1% 100% 140
273
Current averaging range 0 to 400Hz, 9999 0.01Hz 9999 140
High-speed
frequency
control
274
Current averaging filter constant 1 to 4000 1 16 140
275
Stop-on-contact exciting current low-
speed multiplying factor (Note 5)
0 to 1000%, 9999 1% 9999 143
Stop on
contact
276
Stop-on-contact PWM carrier frequency
(Note 5)
0, 1, 2, 9999 1 9999 143