PARAMETERS
20
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Settin
g
Increments
Factory Setting
Refer To
Page:
<Note9>
107
V/F4 (fourth frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 98
108 V/F5 (fifth frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98
5-point flexible V/F
characteristics
109
V/F5 (fifth frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 98
110 Third acceleration/deceleration time
0 to 3600 sec/
0 to 360 sec, 9999
0.1 sec/
0.01 sec
9999 99
111 Third deceleration time
0 to 3600 sec/
0 to 360 sec, 9999
0.1 sec/
0.01 sec
9999 99
112 Third torque boost (Note 1) 0 to 30.0%, 9999 0.1% 9999 99
113 Third V/F (base frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 99
*114 Third stall prevention operation current 0 to 150% 0.1% 150% 99
115 Third stall prevention operation frequency 0 to 400Hz 0.01Hz 0 99
Third functions
116 Third output frequency detection 0 to 400Hz, 9999 0.01Hz 9999 99
117 Station number 0 to 31 1 0 99
118 Communication speed 48, 96, 192 1 192 99
119 Stop bit length/data length
0, 1 (data length 8)
10, 11 (data length 7)
1199
120 Parity check presence/absence 0, 1, 2 1 2 99
121 Number of communication retries 0 to 10, 9999 1 1 99
122 Communication check time interval
0, 0.1 to 999.8 sec,
9999
0.1 0<9999> 99
123 Waiting time setting 0 to 150ms, 9999 10ms 9999 99
Communication functions
124 CR, LF presence/absence selection 0,1,2 1 1 99
128 PID action selection 10, 11, 20, 21 1 10 109
129 PID proportional band 0.1 to 1000%, 9999 0.1% 100% 109
130 PID integral time 0.1 to 3600 sec, 9999 0.1 sec 1 sec 109
131 Upper limit 0 to 100%, 9999 0.1% 9999 109
132 Lower limit 0 to 100%, 9999 0.1% 9999 109
133 PID action set point for PU operation 0 to 100% 0.01% 0% 109
PID control
134 PID differential time 0.01 to 10.00 sec, 9999 0.01 sec 9999 109
135
Commercial power supply-inverter
switch-over sequence output terminal
selection
0, 1, 2 1 0 116
136 MC switch-over interlock time 0 to 100.0 sec 0.1 sec 1.0 sec 116
137 Start waiting time 0 to 100.0 sec 0.1 sec 0.5 sec 116
138
Commercial power supply-inverter
switch-over selection at alarm occurrence
0, 1 1 0 116
Commercial power supply-
inverter switch-over
139
Automatic inverter-commercial power
supply switch-over frequency
0 to 60.00Hz, 9999 0.01Hz 9999 116
140
Backlash acceleration stopping
frequency (Note 7)
0 to 400Hz 0.01Hz 1.00Hz 119
141
Backlash acceleration stopping time
(Note 7)
0 to 360 sec 0.1 sec 0.5 sec 119
142
Backlash deceleration stopping
frequency (Note 7)
0 to 400Hz 0.01Hz 1.00Hz 119
Backlash
143
Backlash deceleration stopping time
(Note 7)
0 to 360 sec 0.1 sec 0.5 sec 119
Display
144 Speed setting switch-over
0, 2, 4, 6, 8, 10, 102,
104, 106, 108, 110
1 4 119
*148 Stall prevention level at 0V input 0 to 150% 0.1% 120% 58
Additional