Raymarine ST1000 Plus & ST2000 Plus Marine Instruments User Manual


 
48 ST1000 Plus & ST2000 Plus Tiller Pilots - Owners Handbook
4 Installing the Tiller Pilot
If required, the tiller pilot can be wired to the SeaTalk bus using a
suitable SeaTalk interface cable (part numbers: D229 flat moulded
plug, D179 male round plug, D181 female round plug).
Connect the SeaTalk cable to the tiller pilot socket as shown below.
As well as sharing SeaTalk data, the tiller pilot can also be used to
supply power to the SeaTalk instruments.
Raymarine produce a range of SeaTalk accessory cables you can use
to connect the tiller pilot to SeaTalk instruments and control units:
flat plugs for recent SeaTalk equipment (e.g. ST30, ST40, ST60)
round plugs for older SeaTalk equipment (e.g. ST50)
Conversion cables - flat moulded plug to round plug
Extension cables - flat moulded plugs at each end
D5554-1
Part no. Type Length
D187 Flat moulded plug to male round plug 0.15 m (6 in)
D188 Flat moulded plug to female round plug 0.3 m (12 in)
Interface cables - flat moulded/round plug to bare ends
Part no. Type Length
D229 Flat moulded plug to bare ends 1 m (3 ft 3 in)
D179 Male round plug to bare ends 3 m (9 ft 10 in)
D181 Female round plug to bare ends 3 m (9 ft 10 in)
Part no. Type Length
D284 Flat moulded plugs at each end 1 m (3 ft 3 in)
D285 Flat moulded plugs at each end 3 m (9 ft 10 in)
D286 Flat moulded plugs at each end 5 m (16 ft 5 in)
D287 Flat moulded plugs at each end 9 m (29 ft 6 in)
D288 Flat moulded plugs at each end 20 m (65 ft 6 in)
Extension cables - round plugs at each end
Part no. Type Length
D124 Male round plug to female round plug 1 m (3 ft 3 in)
D125 Male round plug to female round plug 3 m (9 ft 10 in)
D126 Male round plug to female round plug 6 m (19 ft 8 in)
D154 Male round plug to female round plug 9 m (29 ft 6 in)
81130_3.book Page 48 Wednesday, July 25, 2001 11:57 AM