MODULE #3 - PROGRAM FUNCTIONS ACCESSIBLE W/ FRONT PANEL LOCKOUT
This programming module programs what is accessible through the front
panel when the PGM. DIS. pin is connected to common (COMM.).
Note:Theterm“QuickProgramming”isusedtorefertotheabilitytochangethe
informationthatcan beaccessedfrom thefrontpanel whenthe“PGM. DIS.”
terminal is connected to “COMM.”.
DISPLAY ALARM VALUES
Ifthealarmoptionisinstalled,thisselectswhetherthealarmvalueswillor
will not be displayed.
“dSP AL” < > “yES” or “NO”
ENTER ALARM VALUES =
If “YES” was selected for display alarm values, this will select if alarm
values may be modified from the front panel. (If “NO” was selected for
display alarm values, then this step will default to “NO” and will not be
displayed for selection.)
“ENt AL” < > “yES” or “NO”
DISPLAY HYSTERESIS VALUES
If the alarm option is installed, this selects whether the hysteresis values
will or will not be displayed.
“dSPHYS” < > “yES” or “NO”
ENTER HYSTERESIS VALUES =
If “YES” was selected for display hysteresis values, this selects whether
hysteresis values may be modified from the front panel. (If “NO” was
selected for display hysteresis value, then this step will default to “NO” and
will not be displayed for selection.)
“ENtHYS” < > “yES” or “NO”
=Note:Thissequencemaybelocked-outduetootherprogrammedsequences.
*Note:Thisfunctionoperatesindependentofthestateofthe“PGM.DIS.”pin.
RESET LATCHED ALARMS
If the alarm optionis installed and if either alarmis programmed to latch,
this will select if a latched alarm(s) can be reset from the front panel.
“rSt AL” < > “yES” or “NO”
DISPLAY PEAK/VALLEY MEMORY BUFFER
If the integrator/totalizeroption is installed, this selects whether peak and
valley buffers will be displayed.
“dSPbUF” < > “yES” or “NO”
RESET PEAK/VALLEY MEMORY BUFFER =
If “YES” wasselected for the previous step, this selects whether the peak
and valley buffers may bereset fromthe frontpanel. (If“NO” wasselected,
then this step defaults to “NO” and will not be displayed for selection.)
“rStbUF” < > “yES” or “NO”
SELECT DISPLAY*
If the integrator/totalizer option is installed, this selects whether the
display can be switched from input display to total display and from total
display to input display.
Note:When“NO”isselected, whateverdisplay(Inputortotal) isshown,willbe
the only display accessible.
“SELdSP” < > “yES” or “NO”
RESET TOTAL*
If the integrator/totalizer option is installed, this selects whether the total
can be reset from the front panel.
“rSttOt” < > “yES” or “NO”
-9-