PROGRAMMING AND OPERATING THE IMY
PROGRAMMING THE IMY
Although the unit has been programmed at the factory, the set-ups will
generallyhave tobechanged tosuit theapplication.Basic set-upis complete
after selection of the temperature units, decimal point placement, and
selection of the digital filtering level.
Beforeactuallytryingtoprogramtheindicator,itisadvisedtoorganizeall
the data for the programming steps to avoid any possible confusion and to
read the programming procedure entirely before proceeding.
To set-up the indicator, connect primary power and signal wires as
outlined in the connections section (Appendix “A”). Remove the jumper
wire(ifinstalled)fromTBA#3(PGM.DIS.).Thiswillallowtheoperatorto
enter and modify all of the indicator’s parameters. Press the front panel
button labeled “P”, momentarily. Briefly, the display will show “Pro”
alternately flashing with “0”. This is the indicator’s programming mode.
The programming mode is divided into sections, numbered 0-9, each of
which can be individually accessed. The front panel “UP” and “DOWN”
arrowbuttonscanbeusedtoselectoneofthesenumbersandthe“P”button
can be used to enter the selected programming module. In all of the
programmingmodules,“UP”and“DOWN”areusedtoeitherselectfroma
listofchoicesorentera value.The“P”buttonisusedtosave thenewvalue
and progress to the next step within a module (Note: the new value takes
effect when “P” is pressed). Upon completion of a module, the indicator
returns to the “Pro” <>“0” stage. Pressing the “P” button at this time
causes the unit to display “End” after which theunit returns to the normal
displaymode.Thefollowingtableexplainsthebasicfunctionofeachstep.
Note: < > This indicates that the display will alternate between the English
prompt and the actual data.