Apollo IMY Marine Instruments User Manual


 
20. CERTIFICATIONS AND COMPLIANCES:
SAFETY
IEC1010-1,EN61010-1:Safetyrequirementsforelectricalequipmentfor
measurement, control and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Type 4 Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY
Immunity to EN 50082-2
Electrostatic discharge EN 61000-4-2 Level2; 4 Kv contact
1
Level 3; 8 Kv air
Electromagnetic RF fields EN 61000-4-3 Level3; 10 V/m
2
80 MHz - 1 GHz
Fast transients (burst) EN 61000-4-4 Level4; 2 Kv I/O
Level 3; 2 Kv power
RF conducted interference EN 61000-4-6 Level 3; 10 V/rms
150 KHz - 80 MHz
Emissions to EN 50081-2
RF interference EN 55011 Enclosure class A
Power mains class A
Notes:
1.Metalbezel ofunitconnected withgroundleadfrom rearbezelscrew tometal
mounting panel.
2. Self-recoverable loss of performance during EMI disturbance at 10 V/m:
Processinputand/oranalogoutputsignalmayvaryduringEMIdisturbance.
For operation without loss of performance:
Unit is mounted in a metal enclosure (Buckeye SM7013-0 or equivalent)
I/Oandpowercablesareroutedinmetalconduitconnectedtoearthground.
Refer to the EMC Installation Guidelines for additional information.
21.CONSTRUCTION:Die-castmetalfrontbezelthatmeetsNEMA4/IP65
requirements for wash-down and/or dusty environments when properly
installed. Pollution Degree 2. Case body is black, high impact plastic
(panel gasket and mounting clips included).
22. CONNECTION: Removable terminal blocks
23. WEIGHT: 1.2 lbs. (0.54 kg)
-40-