Apollo IMY Marine Instruments User Manual


 
ALARM #2 ASSIGNMENT TO INPUT OR INTEGRATOR/
TOTALIZER
Alarm #2 may be programmed to activate on either the input or the
integrator/totalizer value. If the integrator/totalizer option is not installed,
this step defaults to the input.
“ASN-2” < > “INPUt”or “totAL”
PROGRAM VALUE FOR ALARM #2
The range of the alarm value is -999 to 9,999 for the input display and
-99999 to 999999 for the totalizer option display.
“AL-2” < > “-999” to “9999”
PROGRAM HYSTERESIS VALUE FOR ALARM #2
(Cannot be programmed if alarm latch is programmed)
The hysteresis(deadband) value for alarm #2may beprogrammed from 1
to 9,999 for the input and 1 to 999999 for the totalizer option. The value is
either added to or subtractedfrom thealarm value depending on whether the
alarm is high or low acting. (See “alarms” section for operation.)
“HyS-2” < > “1” to “9999”
ALARM #2 HIGH OR LOW ACTING
Theactionofalarm#2maybeprogrammedtoactivateeitherwhenthedisplay
value goes above the alarm value (high acting) or goes below it (low acting).
“Act-2” < > “HI” or “LO”
Note:Depending onoptionsselected underPro3 andPro 6,alarms, hysteresis,
peak,and valleyvaluescan bemonitored and/orchangedwhen PGM.DIS.is
tiedtoCOMM.Thisprovidesa“QUICKPROGRAMMING”methodfor“day
today” processchanges. (SeeQUICKPROGRAMMING SECTIONformore
details.)
-15-