Emerson Rosemount 3051CF Marine Instruments User Manual


 
March 2014 Quick Start Guide
Brazil
E2 INMETRO Flameproof
Certificate: UL-BR 13.0643X
Standards: ABNT NBR IEC60079-0:2008 + Errata 1:2011, ABNT NBR IEC60079-1:2009 +
Errata 1:2011, ABNT NBR IEC60079-26:2008 + Errata 1:2008
Markings: Ex d IIC T6/T5 Ga/Gb, T6(-50°C Ta +65°C), T5(-50°C Ta +80°C)
Special Conditions for Safe Use (X):
1.
This device contains a thin wall diaphragm. Installa
tion, maintenance and use shall take
into account the environmental conditions to w
hich the diaphragm wi
ll be subjected. The
manufacture
r’s instructions for installation and maintenance shall be followed in det
ail to
assure safet
y duri
ng its expected lifetime.
2.
In case of repair, contact the manufacturer for information on the di
mensions of the
flameproof joints.
3.
The capacitance of the wrap around label, being 1.6nF, exceeds the
limit in Table 9 of
ABNT NBR IEC
60079-0. The user shall determine suitability for the specific applicat
ion.
I2
INMETRO Intrinsic Safety
Certificate: UL-BR 13.0584X
Standards: ABNT NBR IEC60079-0:2008 + Errata 1:2011, ABNT NBR IEC60079-11:2009
Markings: HART: Ex ia IIC T5/T4 Ga, T5(-60°C Ta +40°C), T4(-60°C Ta +70°C)
Fieldbus/PROFIBUS: Ex ia IIC T4 Ga (-60°C Ta +60°C)
Input Parameters
HART Fieldbus/PROFIBUS
Voltage U
i
30 V 30 V
Current I
i
200 mA 300 mA
Power P
i
0.9 W 1.3 W
Capacitance C
i
0.012 µF 0 µF
Inductance L
i
0 mH 0 mH
Special Conditions for Safe Use (X):
1.
If the equipment is fitted with an optional 90V trans
ient suppressor, it is not capable of
w
ithstanding the 500V insulation test required by ABNT NBR IRC 60079-11:2008. Th
is
must be taken into account when i
nstalling the equipment.
2.
The enclosure may be made of aluminum alloy and given a protective polyurethane
paint
finish; how
ever, care should be taken to protect it from impact or ab
rasion if located in
Zone 0.
IB INMETR
O FISCO
Certificate: UL-BR 13.0584X
Standards: ABNT NBR IEC60079-0:2008 + Errata 1:2011, ABNT NBR IEC60079-11:2009
Markings: Ex ia IIC T4 Ga (-60°C Ta +60°C)
Input Parameters
FISCO
Voltage U
i
17.5 V
Current I
i
380 mA
Power P
i
5.32 W
Capacitance C
i
<5 nF
Inductance L
i
<10 µH
Special Conditions for Safe Use (X):
1.
If the equipment is fitted with an optional 90V trans
ient suppressor, it is not capable of
w
ithstanding the 500V insulation test required by ABNT NBR IRC 60079-11:2008. Th
is
must be taken into account when i
nstalling the equipment.
2.
The enclosure may be made of aluminum alloy and given a protective polyurethane
paint
finish; how
ever, care should be taken to protect it from impact or ab
rasion if located in
Zone 0.