Emerson Rosemount 3051CF Marine Instruments User Manual


 
March 2014 Quick Start Guide
Power P
i
0.9 W 1.3 W 5.32 W
Capacitance C
i
0.012 µF 0 µF <5 nF
Inductance L
i
0 mH 0mH <10 µH
Note 1: FISCO parameters apply to both Group IIC and IIB.
Note 2: [For Flowmeters] When 644 temperature transmitter is used, the 644
temperature transmitter should be used with Ex-certified associated apparatus to
establish explosion protection system that can be used in explosive gas atmospheres.
Wiring and terminals should comply with the instruction manual of both 644 temperature
transmitter and associated apparatus. The cables between 644 temperatures transmitter
and associated apparatus should be shielded cables (the cables must have insulated
shield). The shielded cable has to be grounded reliably in a non-hazardous area.
4.
Transmitters comply with the requirements for FISCO field dev
ices specified in
IEC60079-
27:2008. For the connection of an intrinsically safe circuit in accordance wi
th
FISCO
Model, FISCO paramete
rs are listed in the table above.
5.
The product should be used with Ex-certified associated apparatus
to establish
explosion protect
ion system that can be used in explosive gas atmo
spheres. Wiring and
terminals should comply
with the instruction manual of the product a
nd associated
apparatus.
6.
The cables between this product and associated apparatus should
be shielded cables
(the cables must have insulated shield). The shielded cable has to b
e grounded reliably
in a non-hazardous area.
7.
End users are not permitted to change any intern components but to settle the probl
em
in conjunction w
ith the manufacturer to avoid damage to the product.
8.
During installation, use and maintenance of this product, observe the followi
ng
standards:
GB3836.1
3-1997 “Electrical apparatus for explosive gas atmospheres Part 13: Repai
r
and overhaul fo
r apparatus used in explosive gas atmospheres”
GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15: Electr
ical
installations in hazardous area (other than mines)”
GB3836.16-2006 “Electrical apparatus for explosive gas atmospher
es Part 16:
Inspection and maintenance of ele
ctrical installation (other than mine
s)”
GB50257
-1996 “Code for construction and acceptance of electric dev
ice for explosion
atmospheres an
d fire hazard electrical equipment installation engineering”.
GB12476.2-2006 “Electrical apparatus for use in the presence of co
mbustible dust Part
1-2: Electrical apparatus prot
ected by enclosures and surface temperature limitation-
Selection, installation and maintenance”
GB15577-2007 “Safety regulations for dust explosion prevention and protection”
N3 China Type n
Certificate: GYJ101111X
Standards: GB3836.1-2000, GB3836.8-2003
Markings: Ex nA IIC T5 (-40°C Ta +70°C)
Special Conditions for Safe Use (X):
1.
Symbol “X” is used to denote specific conditions of use: The appara
tus is not capable of
w
ithstanding the 500V test to earth for one minute. The must be tak
en into consideration
during installation.
2.
The ambient temperature range is -40°C Ta +70°C.
3.
Maximum input voltage: 55V.
4.
Cable glands, conduit or blanking plugs, certified by NEPSI with Ex e or Ex n prot
ection
t
ype and IP66 degree of protection provided by enclosure, should be used on extern
al
connections and redundant cable entries.
5.
Maintenance should be done in non-hazardo
us location.
6.
End users are not permitted to change any internal components but to settle the probl
em
in conjunction w
ith manufacturer to avoid damage to the prod
uct.
7.
During installation, use and maintenance of this product, observe the followi
ng
standards:
GB3836.1
3-1997 “Electrical apparatus for explosive gas atmospheres Part 13: Repai
r
and overhaul fo
r apparatus used in explosive gas atmospheres”