13. INSTALLATION
13-7
3. Wipe off any sandpaper dust from the face of the transducer.
4. Dry the face of the transducer and the hull. Coat the transducer face and mounting
location with silicone sealant. Hardening begins in approx. 15-20 minutes so do
this step without delay.
5. Attach the transducer to the hull.
Press the transducer firmly down on the hull
and gently twist it back and forth to remove
any air which may be trapped in the silicone
sealant.
6. Support the transducer with a piece of wood
to keep it in place while the sealant is drying.
It takes 24-72 hours to harden completely.
13.3.4 Triducer
DO NOT overtighten screws, to prevent damage to the transducer.
525STID-MSD
The optional triducer 525STID-MSD is designed for thru-hull mounting.
525STID-PWD
The optional transom mount triducer 525STID-PWD can be installed by the thru-hull
method or the inside-hull method.
Transducer
Silicone
Sealant
Hull
Silicone
Sealant
ø
79
133
2.00"-12 UN
threads
ø
51
7
27
140
Unit: mm
BOW