13. INSTALLATION
13-13
8. Launch your boat and check for water leakage around the sensor.
13.4.2 Temperature sensors
Transom mount temperature sensor T-02MTB
Fix the cable at a convenient location on the transom with the cable clamp.
When the cable is led through the transom board, make a hole of approx. 17 mm in
diameter to pass the connector. After passing the cable, seal the hole with a sealing
compound.
Thru-hull mount temperature sensor T-02MSB, T-03MSB
Select a suitable mounting location considering the following points:
Select a mid boat flat position.
Select a location where the transducer will not be damaged in trailering, launching,
hauling, and storage.
Locate away from equipment which gives off heat.
Locate away from drain pipes.
Select a location where vibration is minimal.
Install the sensor as shown on the next page.
Locknut
123
Face "notch"
toward bow.
Flange nut
51
Brim
ø
77
Coat with
silicone sealant.
Unit: mm
D
5x20
D
>
50 cm
=
Flush with hull bottom.