13. INSTALLATION
13-14
Sensor
cable
8 m
Locknut
Coat with
sealant.
Plate thick-
ness within
25 mm
Coat with
sealant.
ø21 mm
ø25 mm
Washer
Gasket
Locknut
Locknut
Washer
Gasket
Holder Guide
Sensor Holder
T-02MSB T-03MSB
ø42
70
M20
M24
70
ø50
Cable
8 m
Mounting procedure
1. Drill a hole of 21 mm in diameter in
the mounting location.
2. Pass the sensor cable through the
hole.
3. Pass gasket, washer and locknut
onto cable in that order.
4. Coat the sensor flange with high
quality sealant and then fasten the
sensor with the locknut.
(Torque: max. 59N·m)
5. Launch the boat to check for water
leakage around the sensor.
Mounting procedure
1. Drill a hole of 25 mm in diameter in the
mounting location.
2. Coat holder guide with high quality sealant, and
pass gasket, washer and locknut onto holder
guide in that order and then tighten the locknut.
3. Set the sensor holder to the holder guide from
inside the boat and then tighten the locknut.
4. Launch the boat to check for water leakage
around the sensor.