Wiring
2.3.5 Assigning signals (output stop signal (MRS), reset signal (RES), etc.) to contact
input terminals
POINT
y Use parameters (Pr.178 to Pr.182 input terminal function selection) to select and change the functions assigned to
input terminals.
To assign the output stop signal (MRS) to the terminal RH, for example, assign "24" to Pr.182 RH terminal
function selection. Refer to page 4 to change the parameter setting.
y Set Pr.160 Extended function display selection = "0" (extended parameters enabled).
Parameter Name Unit
Initial
value
Range
178
STF terminal
function selection
160
0: Low-speed operation command (RL)
1: Middle-speed operation command (RM)
2: High-speed operation command (RH)
3: Second function selection (RT)
4: Terminal 4 input selection (AU)
5: Jog operation selection (JOG)
7: External thermal relay input (OH)
8: 15-speed selection (REX)
10: Drive unit run enable signal (X10)
(FR-HC/FR-CV connection)
12: PU operation external interlock (X12)
14: PID control valid terminal (X14)
16:
PU/External operation switchover (X16)
23: Pre-excitation/servo ON (LX)
24: Output stop (MRS)
25: Start self-holding selection (STOP)
60:
Forward rotation command (STF)
∗1
61:
Reverse rotation command (STR)
∗2
62: Drive unit reset (RES)
64:
PID forward/reverse action switchover (X64)
65:
PU/NET operation switchover (X65)
66:
External/NET operation switchover (X66)
67: Command source switchover (X67)
72: PID integral value reset (X72)
9999: No function
∗1 Assignable to the STF terminal (Pr.178)
only.
∗2 Assignable to the STR terminal (Pr.179)
only.
179
STR terminal
function selection
161
180
RL terminal
function selection
10
181
RM terminal
function selection
11
182
RH terminal
function selection
12
NOTE
y Changing the terminal assignment using Pr.178 to Pr.182 (input terminal function selection) may affect other functions. Set
parameters after confirming the function of each terminal.