Parameter list
6
124
PU communication CR/LF
selection
0, 1, 2 1
125
Terminal 2 speed setting gain
speed
0 to 12000r/min/
0 to 8000r/min *
1
3000r/min
126
Terminal 4 speed setting gain
speed
0 to 12000r/min/
0 to 8000r/min *
1
3000r/min
127
PID control automatic
switchover speed
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
128 PID action selection 0, 20, 21 0
129 PID proportional band
0.1 to 1000%,
9999
100%
130 PID integral time
0.1 to 3600s,
9999
1s
131 PID upper limit
0 to 100%,
9999
9999
132 PID lower limit
0 to 100%,
9999
9999
133 PID action set point
0 to 100%,
9999
9999
134 PID differential time
0.01 to 10s,
9999
9999
144 Speed setting switchover
2, 4, 6, 8, 10,
102, 104,
106, 108,
110
104/106 *
1
145 PU display language selection 0 to 7 0
150 Output current detection level 0 to 200% 150%
151
Output current detection signal
delay time
0 to 10s 0s
152 Zero current detection level 0 to 200% 5%
153 Zero current detection time 0 to 1s 0.5s
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157 OL signal output timer
0 to 25s,
9999
0s
160
Extended function display
selection
0, 9999 9999
161
Speed setting/key lock
operation selection
0, 1, 10, 11 0
166
Output current detection signal
retention time
0 to 10s,
9999
0.1s
167
Output current detection
operation selection
0, 1 0
168
Parameter for manufacturer setting. Do not set.
169
170 Watt-hour meter clear 0, 10, 9999 9999
171 Operation hour meter clear 0, 9999 9999
178 STF terminal function selection
0 to 5, 7, 8,
10, 12, 14,
16, 23 to 25,
60(Pr.178),
61(Pr.179),
62, 64 to 67,
72, 9999
60
179
STR terminal function
selection
61
180 RL terminal function selection 0
181 RM terminal function selection 1
182 RH terminal function selection 2
Parameter
Name
Setting
Range
Initial
Value
190
RUN terminal function
selection
0, 1, 3, 4, 7,
8, 11 to 16,
21, 25, 26,
33, 47, 48,
64, 70, 79,
90, 91,
93(Pr.190),
95, 96,
98 to 101,
103, 104,
107, 108,
111 to 116,
121, 125,
126, 133,
147, 148,
164, 170,
179, 190,
191,
193(Pr.190),
195, 196,
198, 199,
9999
0
192
A,B,C terminal function
selection
99
232 Multi-speed setting (speed 8)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
233 Multi-speed setting (speed 9)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
234 Multi-speed setting (speed 10)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
235 Multi-speed setting (speed 11)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
236 Multi-speed setting (speed 12)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
237 Multi-speed setting (speed 13)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
238 Multi-speed setting (speed 14)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
239 Multi-speed setting (speed 15)
0 to 12000r/min/
0 to 8000r/min *
1
,
9999
9999
241
Analog input display unit
switchover
0, 1 0
244 Cooling fan operation selection 0, 1 1
249
Earth (ground) fault detection
at start
0, 1 0
250 Stop selection
0 to 100s,
1000 to
1100s,
8888, 9999
9999
251
Output phase loss protection
selection
0, 1 1
255 Life alarm status display (0 to 15) 0
256
Inrush current limit circuit life
display
(0 to 100%) 100%
257
Control circuit capacitor life display
(0 to 100%) 100%
258
Main circuit capacitor life display
(0 to 100%) 100%
259
Main circuit capacitor life
measuring
0, 1
(2, 3, 8, 9)
0
267 Terminal 4 input selection 0, 1, 2 0
268
Monitor decimal digits selection
0, 1, 9999 9999
269 Parameter for manufacturer setting. Do not set.
295
Magnitude of speed change
setting
0, 0.01, 0.10,
1.00, 10.00
0
296 Password lock level
1 to 6,
101 to 106,
9999
9999
Parameter
Name
Setting
Range
Initial