Mitsubishi Electronics FR-D700-G Outboard Motor User Manual


 
27
Simple mode parameters
6
6 PARAMETERS
Simple variable-speed operation can be performed with the drive unit in the initial settings. Set the required parameters
according to the load and operating conditions. Use the operation panel to set or change a parameter. (Refer to Chapter 4
of the Instruction Manual (Applied) for the detailed description of parameters.
6.1 Simple mode parameters
POINT
In the initial setting, only the simple mode parameters are displayed by the Pr.160 Extended function display selection
setting. Change the Pr.160 Extended function display selection setting as required. (Refer to page 4 to change the
parameter.
Parameter
Number
Name
Increments
Initial
Value
Range Application
1 Maximum setting 1r/min 3000r/min
0 to12000r/min/
0 to 8000r/min *
Use this parameter to set the upper limit for the rotation
speed.
2 Minimum setting 1r/min 0r/min
0 to 3600r/min/
0 to 2400r/min *
Use this parameter to set the lower limit for the rotation
speed.
4
Multi-speed setting (high
speed)
1r/min 3000r/min
0 to 12000r/min/
0 to 8000r/min *
Use these parameters to change among pre-set
operation speeds with the terminals. The speeds are pre-
set with parameters.
5
Multi-speed setting (middle
speed)
1r/min 1500r/min
0 to 12000r/min/
0 to 8000r/min *
6
Multi-speed setting (low
speed)
1r/min 300r/min
0 to 12000r/min/
0 to 8000r/min *
7 Acceleration time 0.1s 5s 0 to 3600s
Use these parameters to set the acceleration/
deceleration time.
8 Deceleration time 0.1s 5s 0 to 3600s
9 Electronic thermal O/L relay 0.01A
Rated
motor
current
0 to 500A
With this parameter, the drive unit protects the motor from
heat.
Set the rated motor current.
79 Operation mode selection 1 0
0 External/PU switchover mode
1 Fixed to PU operation mode
2 Fixed to External operation mode
3
External/PU combined operation mode 1
(Start command from External, speed command from PU)
4
External/PU combined operation mode 2
(Speed command from External, start command from PU)
6 Switchover mode
7 External operation mode (PU operation interlock)
125
Terminal 2 speed setting gain
speed
1r/min 3000r/min
0 to 12000r/min/
0 to 8000r/min *
Use this parameter to change the speed at the maximum
potentiometer setting (5V in the initial setting)
126
Terminal 4 speed setting gain
speed
1r/min 3000r/min
0 to 12000r/min/
0 to 8000r/min *
Use this parameter to change the speed at the maximum
current input (20mA in the initial setting)
160
Extended function display
selection
19999
0
Simple mode + extended mode parameters are
displayed.
9999 Only the simple mode parameters are displayed.
999 Automatic parameter setting 1 9999 10, 9999
Communication parameter settings for Mitsubishi's
human machine interface (GOT) connection are changed
as a batch.
Pr.CL Parameter clear 1 0 0, 1
Setting "1" returns all parameters except calibration
parameters to the initial values.
ALLC All parameter clear 1 0 0, 1 Setting "1" returns all parameters to the initial values.
Er.CL Fault history clear 1 0 0, 1 Setting "1" clears eight past faults.
Pr.CH Initial value change list ⎯⎯
Displays and sets the parameters changed from the initial
value.
AUTO Automatic parameter setting ⎯⎯
Communication parameter settings for Mitsubishi's
human machine interface (GOT) connection are changed
as a batch.
* Range depends on the drive unit capacity. (0.2K to 2.2K/3.7K)