Furuno CSH-8L SONAR User Manual


 
APPENDIX
AP-4
Installation when retraction tank is 600 to 750 mm long
1. Follow steps 1 through 5 in the previous procedure.
2. Set the transducer travel to 450 mm by changing the position of the upper limit switch.
Upper limit switch
Move upper limit switch
to modify to 450 mm travel.
3. Assemble the hull unit, taking the following points into account. Refer to Chapter 1 for
assembly instruction.
Note 1: The tank guide should be installed at the position 162 mm above the top of the
transducer flange.
Tank guide
162 mm
*
*: Measure between the top of the
transducer flange and the inner edge
of the tank guide.
Note 2: The shaft retainer should be in contact with the waterproofing attachment.