Mitsubishi Electronics FR-D740-0.4K to 15K Marine Battery User Manual


 
32
Parameter list
7
84 Rated motor frequency 10 to 120Hz 60Hz
90 Motor constant (R1) 0 to 50Ω , 9999
9999
96 Auto tuning setting/status 0, 11, 21 0
117
PU communication station
number
0 to 31
(0 to 247)
0
118 PU communication speed 48, 96, 192, 384 192
119
PU communication stop bit
length
0, 1, 10, 11 1
120
PU communication parity
check
0, 1, 2 2
121
Number of PU communication
retries
0 to 10, 9999 1
122
PU communication check time
interval
0,
0.1 to 999.8s,
9999
0
123
PU communication waiting
time setting
0 to 150ms,
9999
9999
124
PU communication CR/LF
selection
0, 1, 2 1
125
Terminal 2 frequency setting
gain frequency
0 to 400Hz 60Hz
126
Terminal 4 frequency setting
gain frequency
0 to 400Hz 60Hz
127
PID control automatic
switchover frequency
0 to 400Hz, 9999 9999
128 PID action selection
0, 20, 21,
40 to 43
0
129 PID proportional band
0.1 to 1000%,
9999
100%
130 PID integral time
0.1 to 3600s,
9999
1s
131 PID upper limit 0 to 100%, 9999 9999
132 PID lower limit 0 to 100%, 9999 9999
133 PID action set point 0 to 100%, 9999 9999
134 PID differential time
0.01 to 10s,
9999
9999
145 PU display language selection 0 to 7 0
146 ∗5
Built-in potentiometer
switching
0, 1 1
150 Output current detection level 0 to 200% 150%
151
Output current detection signal
delay time
0 to 10s 0s
152 Zero current detection level 0 to 200% 5%
153 Zero current detection time 0 to 1s 0.5s
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157 OL signal output timer 0 to 25s, 9999 0s
160
Extended function display
selection
0, 9999 9999
161
Frequency setting/key lock
operation selection
0, 1, 10, 11 0
162
Automatic restart after
instantaneous power failure
selection
0, 1, 10, 11 1
165
Stall prevention operation level
for restart
0 to 200% 150%
166
Output current detection signal
retention time
0 to 10s, 9999 0.1s
167
Output current detection
operation selection
0, 1 0
168
Parameter for manufacturer setting. Do not set.
169
170 Watt-hour meter clear 0, 10, 9999 9999
171 Operation hour meter clear 0, 9999 9999
Pr.
Name Setting Range
Initial
Value
178 STF terminal function selection
0 to 5, 7, 8, 10,
12, 14, 16, 18,
24, 25, 60
∗6,
61
∗7, 62,
65 to 67, 9999
60
179 STR terminal function selection 61
180 RL terminal function selection 0
181 RM terminal function selection 1
182 RH terminal function selection 2
190
RUN terminal function
selection
0, 1, 3, 4, 7, 8, 11
to 16, 25, 26, 46,
47, 64, 70, 80,
81, 90, 91, 93
∗8,
95, 96, 98, 99,
100, 101, 103,
104, 107, 108,
111 to 116, 125,
126, 146, 147,
164, 170, 180,
181, 190, 191,
193
∗8, 195, 196,
198, 199, 9999
∗9
0
192
A,B,C terminal function
selection
99
197 SO terminal function selection 80
232 Multi-speed setting (speed 8) 0 to 400Hz, 9999 9999
233 Multi-speed setting (speed 9) 0 to 400Hz, 9999 9999
234 Multi-speed setting (speed 10) 0 to 400Hz, 9999 9999
235 Multi-speed setting (speed 11) 0 to 400Hz, 9999 9999
236 Multi-speed setting (speed 12) 0 to 400Hz, 9999 9999
237 Multi-speed setting (speed 13) 0 to 400Hz, 9999 9999
238 Multi-speed setting (speed 14) 0 to 400Hz, 9999 9999
239 Multi-speed setting (speed 15) 0 to 400Hz, 9999 9999
240 Soft-PWM operation selection 0, 1 1
241
Analog input display unit
switchover
0, 1 0
244 Cooling fan operation selection 0, 1 1
245 Rated slip 0 to 50%, 9999 9999
246
Slip compensation time
constant
0.01 to 10s 0.5s
247
Constant-power range slip
compensation selection
0, 9999 9999
249
Earth (ground) fault detection
at start
0, 1 0
250 Stop selection
0 to 100s,
1000 to 1100s,
8888, 9999
9999
251
Output phase loss protection
selection
0, 1 1
255 Life alarm status display (0 to 15) 0
256
Inrush current limit circuit life
display
(0 to 100%) 100%
257
Control circuit capacitor life
display
(0 to 100%) 100%
258
Main circuit capacitor life
display
(0 to 100%) 100%
259
Main circuit capacitor life
measuring
0, 1
(2, 3, 8, 9)
0
260
PWM frequency automatic
switchover
0, 1 0
261 Power failure stop selection 0, 1, 2 0
267 Terminal 4 input selection 0, 1, 2 0
268
Monitor decimal digits
selection
0, 1, 9999 9999
269 Parameter for manufacturer setting. Do not set.
295
Magnitude of frequency
change setting
0, 0.01, 0.10,
1.00, 10.00
0
296 Password lock level
1 to 6,
101 to 106, 9999
9999
297 Password lock/unlock
1000 to 9998 (0
to 5, 9999)
9999
298 Frequency search gain 0 to 32767, 9999 9999
299
Rotation direction detection
selection at restarting
0, 1, 9999 0
338
Communication operation
command source
0, 1 0
Pr.
Name Setting Range
Initial
Value