Topcon GPT-2005 Marine Instruments User Manual


 
22 ERROR DISPLAYS
22-1
22 ERROR DISPLAYS
Error code
Description Countermeasures
3 points
required
When area calculating, there are less
than 3 points coordinate data in
selected le.
Conrm the le data and calculate
again.
CALC
ERROR
Calculation is impossible from the
data input.
Conrm the input data.
DELETE
ERROR
When deleting coordinate data, it can not
be done successful.
Conrm the data and delete again.
SIGNAL
OVER
Displayed when you measure a prism of short
distance with non-prism mode, or when the
telescope received too much light.
Measure the distance by using a target
without using a prism, or change the mode
from non-prism mode to prism mode.
E35
Displayed when REM measurement
carried out to the range from zenith or
nadir ±6°.
Operate in the range out of ± 6° from the
zenith or nadir.
E60’s
Any abnormality occurs with EDM (distance
measuring system).
Repair is required.
E71
Displayed when vertical angle 0 position is
set with incorrect procedure.
Conrm the procedure and readjust.
E72
Displayed when Vertical angle -position is
adjusted in wrong position.
Repair is required.
E73
The instrument was not leveled when Vertical
angle 0-position is adjusted.
Level the instrument then carry the
adjustment work.
E80’s
Mainly at the time data transmission
between GPT-2000 series and external
instrument.
Conrm operation procedure is correct or the
connection cables are correct.
E90’s
Abnormality in internal memory
system.
Repair is required.
FILE
EXISTS
The same le name exists. Use another le name.
FULL
FILES
When making a le, 30 les already exist. If necessary, send or delete les.
FAILED
INITIALIZE
Initializing can not be done successful. Conrm initializing data and try to
initialize again.
LIMIT
OVER
Limit of input data exceeded. Input again.
MEMORY
ERROR
Any abnormality occurs with internal
memory.
Initialize the internal memory.
MEMORY
POOR
Shortage of capacity of the internal
memory.
Download data from internal memory
to PC.
NO DATA
The data is not found in the search
mode
Conrm the data and search again.
NO FILE There is no le in internal memory. If necessary, make les.
FILE NOT
SELECTED
When using a le, no le is selected. Conrm the le and select a le.
P1-P2
distance
too short
When in point to line measurement, the
horizontal distance between rst point and
second point is within 1m.
The horizontal distance between rst
point and second point must be more
than 1m.