Topcon GPT-2005 Marine Instruments User Manual


 
6 SPECIAL MODE (Menu Mode)
6-16
6.2 Setting the GRID FACTOR
GRID FACTOR can reset in this menu mode.
For more information, refer to Section 8.1.1”Setting the GRID FACTOR”
Operating procedure Operation Display
1 After pressing the [MENU] key, press the [F4](P
)
key to get the menu on page 2.
[MENU]
[F4]
2 Press the [F2](GRID FACTOR) key.
[F2]
3 Press the [F3](YES) key.
4 Press the [F1] (INPUT) key and enter Elevation.
*1) Press the [F4](ENT) key.
[F3]
[F1]
Enter ELEV.
[F4]
5 Enter Scale Factor in the same way.
[F1]
Enter Scale
[F4]
Grid Factor is displayed for 1 to 2 second and
display returns to menu.
*1) Refer to Section 2.6 “How to Enter Alphanumeric characters”.
Input Range :Elevation : –9,999 to +9,999 meter (–32,805 to +3,2805 ft, ft+in)
Scale Factor: 0.990000 to 1.010000
MENU 2/3
F1:PROGRAMS
F2:GRID FACTOR
F3:ILLUMINATION P
GRID FACTOR
=0.998843
>MODIFY? [YES][NO]
GRID FACTOR
ELEV.1000 m
SCALE:0.999000
INPUT ––– ––– ENTER
1234 5678 90. –[ENT]
GRID FACTOR
ELEV.:2000 m
SCALE
1.001000
INPUT ––– ––– ENTER
GRID FACTOR
=1.000686