Toshiba Single-phase 200V class 0.2 to 2.2kW Marine Battery User Manual


 
E6581090
K-1
11
11. Table of parameters and data
11.1 User parameters
Title Function Unit
Minimum setting
unit Panel/
Communication
Adjustment range
Default
setting
User
setting
Reference
HE Operation frequency of
operation panel
Hz 0.1/0.01
NNWN
0.0 3.1.2
11.2 Basic parameters
Title
Communication
No.
Function Unit
Minimum setting
unit Panel/
Communication
Adjustment range
Default
setting
User
setting
Reference
CWJ
- History function - - Display latest 5
changed parameters
as a group.
*Parameters can be
edited within a
group.
-4.1.3
CWH -Wizard function - - 0:-
1:Basic setting wizard
2:Preset speed
operation wizard
3:Analog signal
operation wizard
4:Motor 1/2 switching
operation wizard
5:Torque up wizard *1
04.1.3
EOQF 0003 Command mode
selection
--0:Terminal block
1:Operation panel
15.1
HOQF 0004 Frequency setting
mode selection
--0:Terminal block
1:Operation panel
2:Internal
potentiometer
3:Serial
communication
4:Terminal
block/internal
potentiometer
switching
25.1
HOUN 0005 FM/OUT terminal
functions selection
---1: Open collector
output
0:Output frequency
1:Output current
2:Set frequency
3:For adjustment
(current fixed at
100%)
4:For adjustment
(current fixed at
50%)
5:For adjustment
(output of max.
frequency
6:For adjustment
(display of gain)
05.2
HO 0006 Meter adjustment - - - - 5.2
*1: This parameter is valid only for VFNC1 (S)-□□□□P-W type.