Toshiba Single-phase 200V class 0.2 to 2.2kW Marine Battery User Manual


 
E6581090
K-10
11
Table of input terminal functions 2
Function
No.
Code Function Action
29 R+SS4
Combination of reverse run and preset
speed command 4
ON : Simultaneous input of R and SS4
commands
30 F+SS1+AD2
Combination of forward run, preset
speed command 1 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS1 and
AD2 commands
31 R+SS1+AD2
Combination of reverse run, preset
speed command 1 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS1 and
AD2 commands
32 F+SS2+AD2
Combination of forward run, preset
speed command 2 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS2 and
AD2 commands
33 R+SS2+AD2
Combination of reverse run, preset
speed command 2 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS2 and
AD2 commands
34 F+SS3+AD2
Combination of forward run, preset
speed command 3 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS3 and
AD2 commands
35 R+SS3+AD2
Combination of reverse run, preset
speed command 3 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS3 and
AD2 commands
36 F+SS4+AD2
Combination of forward run, preset
speed command 4 and
acceleration/deceleration 2
ON : Simultaneous input of F, SS4 and
AD2 commands
37 R+SS4+AD2
Combination of reverse run, preset
speed command 4 and
acceleration/deceleration 2
ON : Simultaneous input of R, SS4 and
AD2 commands
38 FCHG Frequency command forced switching
Enabled if  = 4 (selectable
between terminal board and operation
panel/internal potentiometer)
ON : VI terminal
OFF : Internal potentiometer
39 THR2 No.2 thermal switching
ON : No.2 thermal (:, ,
, , )
OFF : No.1 thermal (: Setting, ,
, , )
40
MCHG No.2 motor switching
ON : No.2 motor (

:0,

,
,

,

,

,

)
OFF : No.1 motor (Pt: Setting, ,
, , , ,
)
49 HD
Operation holding
(Stop of 3-wire operation)
ON : F (forward run) / R (reverse run)
held, 3-wire operation
OFF : Slowdown stop
54 FreeRun Standby (inversion)
ON : Free run
OFF : Standby
55 RSTN Reset signal (inversion) OFF to ON: Trip reset
56 F+ST
Combination of forward run and standby
commands
ON : Simultaneous input of F and ST
commands
57 R+ST
Combination of reverse run and standby
commands
ON : Simultaneous input of R and ST
commands
*1 This function is effective after software version V110.
*1