Toshiba Single-phase 200V class 0.2 to 2.2kW Marine Battery User Manual


 
E6581090
L-2
12
Item Specification
Input voltage
1-phase 100V
Applicable motor (kW)
0.1 0.2 0.4 0.75 1.5 2.2
Type
VFNC1S
Form
1001P 1002P 1004P 1007P - -
Capacity (kVA) Note 1)
0.3 0.6 1.0 1.6 - -
Rated output current (A)
Note 2)
0.7 1.4 2.4 4.0 - -
Rated output voltage
Note 3)
3-phase 200V to 230V
Rating
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
1-phase 100V to 115V - 50/60Hz
Allowable fluctuation
Voltage +10%, -15% Note 4), frequency ±5%
Power
supply
Ampere Interrupt
Capacity (A) AIC
1000 1000 1000 1000 - -
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
Self-cooling
Forced
air-cooled
--
Color
Munsel 5Y8/0.5
Charge lamp
LED indicating the charge status of the capacitor in the main circuit
Built-in filter
-
Item Specification
Input voltage
1-phase 200V (built-in EM1 noise filter)
Applicable motor (kW)
0.1 0.2 0.4 0.75 1.5 2.2
Type
VFNC1S
Form
-2002PL 2004PL 2007PL 2015PL 2022PL
Capacity (kVA) Note 1)
-0.50.91.6 2.9 4.1
Rated output current (A)
Note 2)
-1.22.34.07.510.7
Rated output voltage
Note 3)
3-phase 200V to 240V
Rating
Overload current rating
60 seconds at 150%, (50%-reduction value)
Voltage-frequency
1-phase 200V to 240V - 50/60Hz
Allowable fluctuation
Voltage +10%, -15% Note 4), frequency ±5%
Power
supply
Ampere Interrupt
Capacity (A) AIC
-10001000 1000 5000 5000
Protective method
IP20 Enclosed type (JEM 1030)
Cooling method
-Self-cooling Forced air-cooled
Color
Munsel 5Y8/0.5
Charge lamp
None
Built-in filter
EMC noise filter (Class B)
Note)
1. Capacity is calculated at 220V for the 200V models.
2. Indicates rated output current setting when the PWM carrier frequency (parameter H) is 4kHz or
less.
If the PWM carrier frequency setting is fixed above 4 kHz, the rated current needs to be reduced. If the
PWM carrier frequency is set above 4 kHz, it could fall automatically if an over-current flaws during
acceleration or for any other reason, depending on the amount of current that flows.
The default setting of the PWN carrier frequency is 12kHz.
3. Maximum output voltage is the same as the input voltage.
With regard to 100V models, the output voltage may decrease about 10 to 20 % if motor load is applied.
When operating VFNC1 in conjunction with general purpose motor (200V), it is necessary to reduce the
motor load.
4. ±10% when the inverter is used continuously (load of 100%).